This review was unable to find consistent evidence of differences in adherence according to baseline CD4 count. Although this is encouraging for the new recommendations to treat all HIV-positive individuals irrespective of CD4 count, there is a need for additional high-quality studies, particularly among adults initiating ART at higher CD4 cell counts.
BackgroundAccess to point-of-care HIV testing shortens turn-around times, time to diagnosis and reduces loss to follow-up hence minimizing barriers to early linkage to care and treatment among HIV infected infants. Currently samples for early infant HIV diagnosis are sent to centralized testing facilities which are few and located only at specific regions in Kenya. However, there are Point of Care (POC) early infant diagnosis [EID] technologies elsewhere such as SAMBA and ALERE-Q that are yet to be evaluated in Kenya despite the urgent need for data to inform policy formulation regarding EID. The Cepheid GeneXpert HIV-1 Qual (GeneXpert) technology for POC EID offers a great opportunity to minimize HIV associated morbidity, mortality and loss to follow-up through decentralization of early infant HIV testing to the clinics. This technology also allows for same-day results thus facilitating prompt linkage to care.MethodsWe evaluated the GeneXpert HIV Qual EID POC in Homabay County against the standard of care platform, Roche CAP/CTM HIV-1 qualitative PCR, using dried blood spots (DBS). Between February—July 2016, DBS samples were collected from HIV exposed children <18 months of age enrolled in a cross-sectional study. Samples were collected by qualified nurse counselors, and were tested by trained technicians using field based GeneXpert and conventional laboratory based Roche CAP/CTM HIV-1 qualitative PCR. Sensitivity and specificity were determined.ResultsOverall, 3,814 mother/infant pairs were included in the study, out of which 921 infants were HIV exposed as per the mothers’ HIV status and based on the infant’s HIV rapid test. A total of 969 PCR tests were performed, out of which 30 (3.3%) infants were concordantly positive using both platforms. GeneXpert HIV-1 Qual yielded a sensitivity of 94.1% and specificity of 99.8% with an overall error rate of 0.7%.ConclusionOur findings show that GeneXpert HIV-1 Qual performs well compared to CAP/CTM using DBS samples, suggesting that this technology may be adopted in decentralized laboratories as a near POC device. It may contribute to prompt diagnosis of HIV exposed infants hence enabling early linkage to care, thus advancing further gains in EID.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.