Understanding the most efficacious products will allow clinicians to best communicate to patients and consumers the safest products on the market to reduce adverse events, including microbial keratitis, during contact lens use.
Microbial keratitis (MK) is an eye infection caused by opportunistic bacteria or fungi, which may lead to sight-threatening corneal ulcers. These microorganisms can be introduced to the eye via improper contact lens usage or hygiene, or ineffective multipurpose solutions (MPSs) to disinfect daily wear contact lenses. Thus, the patient’s choice and use of these MPSs is a known risk factor for the development of MK. It is then critical to determine the efficacy of popular MPSs against ubiquitous ocular microorganisms. Therefore, we compare the efficacy of nine major MPSs on the global market against four different microorganism species, and with four different common contact lenses. In accordance with International Standards Organization protocol 14729 and 18259, the microorganisms were inoculated into each MPS with and without contact lenses, and held for the manufacturer’s disinfection time, 24 h, and 7 days after challenge with Serratia marcescens or Fusarium spp. Plates were incubated for 2–7 days and plate counts were conducted to determine the number of surviving microorganisms. The majority of MPSs demonstrated significantly higher disinfection efficacies without contact lenses. Broadly, among the microorganisms tested, the OPTI-FREE products (Puremoist, Express, and Replenish) maintained the highest disinfection efficacies at the manufacturer’s stated disinfection time when paired with any contact lens, compared with other MPSs. These were followed closely by RevitaLens and renu Advanced. MPSs containing dual biocides polyquaternium-1 and myristamidopropyl dimethylamine possessed the highest disinfection efficacy against multiple ocular pathogens.
Acanthamoeba keratitis is a serious ocular infection which is challenging to treat and can lead to blindness. While this pathogen is ubiquitous and can contaminate contact lenses after contact with water, its habits remain elusive. Understanding this organism’s natural behavior will better inform us on how Acanthamoeba colonize contact lens care systems. Acanthamoeba trophozoites were allowed to adhere to either a glass coverslip or non-nutrient agar (NNA) within a flow cell with nutrients (Escherichia coli or an axenic culture medium (AC6)) or without nutrients (Ringer’s solution). Images were taken once every 24 s over 12 h and compiled, and videos were analyzed using ImageJ Trackmate software. Acanthamoeba maintained continuous movement for the entire 12 h period. ATCC 50370 had limited differences between conditions and surfaces throughout the experiment. Nutrient differences had a noticeable impact for ATCC 30461, where E. coli resulted in the highest total distance and speed during the early periods of the experiment but had the lowest total distance and speed by 12 h. The Ringer’s and AC6 conditions were the most similar between strains, while Acanthamoeba in the E. coli and NNA conditions demonstrated significant differences between strains (p < 0.05). These results indicate that quantifiable visual tracking of Acanthamoeba may be a novel and robust method for identifying the movement of Acanthamoeba in relation to contact lens care products. The present study indicates that Acanthamoeba can undertake sustained movement for at least 12 h with and without nutrients, on both rough and smooth surfaces, and that different strains have divergent behavior.
Acanthamoeba keratitis (AK) is a serious ocular infection caused by a ubiquitous free-living amoeba, Acanthamoeba. This infection often results in extensive corneal damage and blindness, and is notoriously difficult to cure. While Acanthamoeba is an abundant organism, AK is most associated with contact lens hygiene noncompliance and inadequate contact lens care (CLC) disinfection regimens. Thus, accurate and timely antimicrobial efficacy testing of CLC solutions is paramount. Published methods for antimicrobial efficacy testing of Acanthamoeba trophozoites requires 14 days for results. Presently, alternate and/or rapid methods for evaluating CLC products rarely demonstrate equivalent results compared to commonly-reported methods. Propidium iodide is a cellular stain that can only bind to cells with damaged outer membranes. We evaluated propidium iodide staining as an alternative method for determining the relative antimicrobial efficacy of 11 different CLC products against Acanthamoeba trophozoites. Following exposure to a CLC product, the fluorescence intensity of propidium iodide in an Acanthamoeba population demonstrated a strong correlation to the log reduction determined by established, growth-based Acanthamoeba testing used to evaluate the antimicrobial efficacy of CLC products. Thus, propidium iodide was found to be an effective rapid tool for determining cell death in Acanthamoeba trophozoites following exposure to CLC solutions.
IntroductionAcanthamoeba keratitis is often caused when Acanthamoeba contaminate contact lenses and infect the cornea. Acanthamoeba is pervasive in the environment as a motile, foraging trophozoite or biocide-resistant and persistent cyst. As contact lens contamination is a potential first step in infection, we studied Acanthamoeba’s behavior and interactions on different contact lens materials. We hypothesized that contact lenses may induce aggregation, which is a precursor to encystment, and that aggregated encystment would be more difficult to disinfect than motile trophozoites.MethodsSix clinically and/or scientifically relevant strains of Acanthamoeba (ATCC 30010, ATCC 30461, ATCC 50370, ATCC 50702, ATCC 50703, and ATCC PRA-115) were investigated on seven different common silicone hydrogel contact lenses, and a no-lens control, for aggregation and encystment for 72 h. Cell count and size were used to determine aggregation, and fluorescent staining was used to understand encystment. RNA seq was performed to describe the genome of Acanthamoeba which was individually motile or aggregated on different lens materials. Disinfection efficacy using three common multi-purpose solutions was calculated to describe the potential disinfection resistance of trophozoites, individual cysts, or spheroids.ResultsAcanthamoeba trophozoites of all strains examined demonstrated significantly more aggregation on specific contact lens materials than others, or the no-lens control. Fluorescent staining demonstrated encystment in as little as 4 hours on contact lens materials, which is substantially faster than previously reported in natural or laboratory settings. Gene expression profiles corroborated encystment, with significantly differentially expressed pathways involving actin arrangement and membrane complexes. High disinfection resistance of cysts and spheroids with multi-purpose solutions was observed.DiscussionAggregation/encystment is a protective mechanism which may enable Acanthamoeba to be more disinfection resistant than individual trophozoites. This study demonstrates that some contact lens materials promote Acanthamoeba aggregation and encystment, and Acanthamoeba spheroids obstruct multi-purpose solutions from disinfecting Acanthamoeba.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.