(1) Background: This study compared manually-counted treadmill walking steps from the hip-worn DigiwalkerSW200 and OmronHJ720ITC, and hip and wrist-worn ActiGraph GT3X+ and GT9X; determined brand-specific acceleration amplitude (g) and/or frequency (Hz) step-detection thresholds; and quantified key features of the acceleration signal during walking. (2) Methods: Twenty participants (Age: 26.7 ± 4.9 years) performed treadmill walking between 0.89-to-1.79 m/s (2–4 mph) while wearing a hip-worn DigiwalkerSW200, OmronHJ720ITC, GT3X+ and GT9X, and a wrist-worn GT3X+ and GT9X. A DigiwalkerSW200 and OmronHJ720ITC underwent shaker testing to determine device-specific frequency and amplitude step-detection thresholds. Simulated signal testing was used to determine thresholds for the ActiGraph step algorithm. Steps during human testing were compared using bias and confidence intervals. (3) Results: The OmronHJ720ITC was most accurate during treadmill walking. Hip and wrist-worn ActiGraph outputs were significantly different from the criterion. The DigiwalkerSW200 records steps for movements with a total acceleration of ≥1.21 g. The OmronHJ720ITC detects a step when movement has an acceleration ≥0.10 g with a dominant frequency of ≥1 Hz. The step-threshold for the ActiLife algorithm is variable based on signal frequency. Acceleration signals at the hip and wrist have distinctive patterns during treadmill walking. (4) Conclusions: Three common research-grade physical activity monitors employ different step-detection strategies, which causes variability in step output.
Our study investigated the performance of proximity sensor-based wear-time detection using the GT9X under laboratory and free-living settings. Fifty-two volunteers (23.2 ± 3.8 y; 23.2 ± 3.7 kg/m) participated in either a laboratory or free-living protocol. Lab participants wore and removed a wrist-worn GT9X on 3-5 occasions during a 3-hour directly observed activity protocol. The 2-day free-living protocol used an independent temperature sensor and self-report as the reference to determine if wrist and hip-worn GT9X accurately determined wear (i.e., sensitivity) and non-wear (i.e., specificity). Free-living estimates of wear/non-wear were also compared to Troiano 2007 and Choi 2012 wear/non-wear algorithms. In lab, sensitivity and specificity of the wrist-worn GT9X in detecting total minutes of wear-on and off was 93% and 49%, respectively. The GT9X detected wear-off more often than wear-on, but with a greater margin of error (4.8 ± 11.6 vs. 1.4 ± 1.4 min). In the free-living protocol, wrist and hip-worn GT9X's yielded sensitivity and specificity of 72 and 90% and 84 and 92%, respectively. GT9X estimations had inferior sensitivity but superior specificity to Troiano 2007 and Choi 2012 algorithms. Due to inaccuracies, it may not be advisable to singularly use the proximity-sensor-based wear-time detection method to detect wear-time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.