Chronotropic incompetence (CI) is generally defined as the inability to increase the heart rate (HR) adequately during exercise to match cardiac output to metabolic demands. In patients with heart failure (HF), however, this definition is unsuitable because metabolic demands are unmatched to cardiac output in both conditions. Moreover, HR dynamics in patients with HF differ from those in healthy subjects and may be affected by β-blocking medication. Nevertheless, it has been demonstrated that CI in HF is associated with reduced functional capacity and poor survival. During exercise, the normal heart increases both stroke volume and HR, whereas in the failing heart, contractility reserve is lost, thus rendering increases in cardiac output primarily dependent on cardioacceleration. Consequently, insufficient cardioacceleration because of CI may be considered a major limiting factor in the exercise capacity of patients with HF. Despite the profound effects of CI in this specific population, the issue has drawn limited attention during the past years and is often overlooked in clinical practice. This might partly be caused by a lack of standardized approach to diagnose the disease, further complicated by changes in HR dynamics in the HF population, which render reference values derived from a normal population invalid. Cardiac implantable electronic devices (implantable cardioverter defibrillator; cardiac resynchronization therapy) now offer a unique opportunity to study HR dynamics and provide treatment options for CI by rate-adaptive pacing using an incorporated sensor that measures physical activity. This review provides an overview of disease mechanisms, diagnostic strategies, clinical consequences, and state-of-the-art device therapy for CI in HF.
Parameters using myocardial strain analysis may predict response to cardiac resynchronization therapy (CRT). As the agreement between currently available strain imaging modalities is unknown, three different modalities were compared. Twenty-seven CRT-candidates, prospectively included in the MARC study, underwent cardiac magnetic resonance (CMR) imaging and echocardiographic examination. Left ventricular (LV) circumferential strain was analysed with CMR tagging (CMR-TAG), CMR feature tracking (CMR-FT), and speckle tracking echocardiography (STE). Basic strain values and parameters of dyssynchrony and discoordination obtained with CMR-FT and STE were compared to CMR-TAG. Agreement of CMR-FT and CMR-TAG was overall fair, while agreement between STE and CMR-TAG was often poor. For both comparisons, agreement on discoordination parameters was highest, followed by dyssynchrony and basic strain parameters. For discoordination parameters, agreement on systolic stretch index was highest, with fair intra-class correlation coefficients (ICC) (CMR-FT: 0.58, STE: 0.55). ICC of septal systolic rebound stretch (SRSsept) was poor (CMR-FT: 0.41, STE: 0.30). Internal stretch factor of septal and lateral wall (ISFsep–lat) showed fair ICC values (CMR-FT: 0.53, STE: 0.46), while the ICC of the total LV (ISFLV) was fair for CMR-FT (0.55) and poor for STE (ICC: 0.32). The CURE index had a fair ICC for both comparisons (CMR-FT: 0.49, STE 0.41). Although comparison of STE to CMR-TAG was limited by methodological differences, agreement between CMR-FT and CMR-TAG was overall higher compared to STE and CMR-TAG. CMR-FT is a potential clinical alternative for CMR-TAG and STE, especially in the detection of discoordination in CRT-candidates.Electronic supplementary materialThe online version of this article (doi:10.1007/s10554-017-1253-5) contains supplementary material, which is available to authorized users.
Tissue characterization by CMR provided a good diagnostic yield in this large clinical population of patients with suspected AM. CMR provided incremental diagnostic value to the ESC-PSC by ruling out the diagnosis of AM on one hand and by potentially sparing AM patients from CAG on the other.
End-systolic septal strain was the only parameter with a consistent good relation to reverse remodelling after CRT, irrespective of assessment technique. In clinical practice, this measure can be obtained by any available strain imaging technique and provides predictive value on top of current guideline criteria.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.