Lung cancer is a leading cause of cancer-related death worldwide and in most cases, diagnosis is reached when the tumor has already spread and prognosis is quite poor. For that reason, the research for new biomarkers that could improve early diagnosis and its management is essential. Exosomes are microvesicles actively secreted by cells, especially by tumor cells, hauling molecules that mimic molecules of the producing cells. There are multiple methods for exosome isolation and analysis, although not standardized, and cancer exosomes from biological fluids are especially difficult to study. Exosomes’ cargo proteins, RNA, and DNA participate in the communication between cells, favoring lung cancer development by delivering signals for growth, metastasis, epithelial mesenchymal transition, angiogenesis, immunosuppression and even drug resistance. Exosome analysis can be useful as a type of liquid biopsy in the diagnosis, prognosis and follow-up of lung cancer. In this review, we will discuss recent advances in the role of exosomes in lung cancer and their utility as liquid biopsy, with special attention to isolating methods.
Breath tests used to evaluate carbohydrates malabsorption require baseline H2 and CH4 levels as low as possible. Test cancellation is recommended when exceeding certain cut-offs (H2 ≥ 20 ppm and CH4 ≥ 10 ppm). Although following preparation protocols, many patients have baseline levels above those cut-offs. We investigated if light walking can reduce baseline H2 and CH4 levels. We retrospectively analyzed baseline H2 and CH4 levels from 1552 breath tests. Baseline levels (B1), especially in H2, were lower when obtained at later hours of the day. In those with baseline levels above cut-off, re-sampling (B2) after light walking for one hour, decreased H2 levels 8 ppm (Q1–Q3: 1–18 ppm), and 2 ppm (Q1–Q3: 0–3 ppm) for CH4. Consequently, 40% of tests with elevated B1 levels, presented B2 levels below mentioned cut-offs. Ten percent of tests considered negative when using B1 for calculations, turned positive when using B2 instead. All positive tests when using B1 values, remained elevated when using B2. Re-sampling after light walking for one hour could allow test performance in those with previous elevated baseline levels, avoiding diagnosis delays. Using the second sample for delta calculations identifies positive patients for malabsorption that would have been considered negative.
ObjectivesLactose malabsorption is generally assessed by hydrogen breath testing (HBT). However, this test is not recommended in patients with high baseline hydrogen concentrations (H2B). In addition, breath testing is not recommended in the current situation created by the COVID-19 pandemic, due to the potential infectiveness of the samples. The objective is to assess concordance between HBT and lactose tolerance test (LTT) depending on H2B concentrations.MethodsA total of 430 patients (40 years, Q1–Q3 = 28–54 years; 66.7% women) suspected of lactose malabsorption were included in the study. Breath and heparinized blood samples were collected at baseline and sequentially after the intake of 50 g of lactose, to measure hydrogen in breath and glycemia in blood, respectively.ResultsH2B was <10 ppm in 69.5% of subjects; 10–20 ppm in 14.7%; and >20 ppm in 15.8% of subjects. In patients with H2B <20 ppm, concordance between HBT and LTT was moderate and consistently improved when the cut-off in LTT was set at 15 mg/dL. The increase in hydrogen and glucose correlated negatively (r=−0.389; p<0.05). The increase in glycemia during LTT was not influenced by H2B levels obtained in HBT.ConclusionsLTT emerges as an alternative to HBT to assess lactose malabsorption in the presence of high H2B levels or when breath testing is not recommended by the circumstances. The best concordance was obtained when the cut-off for LTT was set at 15 mg/dL.
Background Extracellular vesicles (EVs), released by most cell types, provide an excellent source of biomarkers in biological fluids. However, in order to perform validation studies and screenings of patient samples, it is still necessary to develop general techniques permitting rapid handling of small amounts of biological samples from large numbers of donors. Results Here we describe a method that, using just a few microliters of patient’s plasma, identifies tumour markers exposed on EVs. Studying physico-chemical properties of EVs in solution, we demonstrate that they behave as stable colloidal suspensions and therefore, in immunocapture assays, many of them are unable to interact with a stationary functionalised surface. Using flocculation methods, like those used to destabilize colloids, we demonstrate that cationic polymers increase EV ζ-potential, diameter, and sedimentation coefficient and thus, allow a more efficient capture on antibody-coated surfaces by both ELISA and bead-assisted flow cytometry. These findings led to optimization of a protocol in microtiter plates allowing effective immunocapture of EVs, directly in plasma without previous ultracentrifugation or other EV enrichment. The method, easily adaptable to any laboratory, has been validated using plasma from lung cancer patients in which the epithelial cell marker EpCAM has been detected on EVs. Conclusions This optimized high throughput, easy to automate, technology allows screening of large numbers of patients to phenotype tumour markers in circulating EVs, breaking barriers for the validation of proposed EV biomarkers and the discovery of new ones. Graphical Abstract
Metastatic melanoma presents, in many cases, oncogenic mutations in BRAF, a MAPK involved in proliferation of tumour cells. BRAF inhibitors, used as therapy in patients with these mutations, often lead to tumour resistance and, thus, the use of MEK inhibitors was introduced in clinics. BRAFi/MEKi, a combination that has modestly increased overall survival in patients, has been proven to differentially affect immune ligands, such as NKG2D-ligands, in drug-sensitive vs. drug-resistant cells. However, the fact that NKG2D-ligands can be released as soluble molecules or in extracellular vesicles represents an additional level of complexity that has not been explored. Here we demonstrate that inhibition of MAPK using MEKi, and the combination of BRAFi with MEKi in vitro, modulates NKG2D-ligands in BRAF-mutant and WT melanoma cells, together with other NK activating ligands. These observations reinforce a role of the immune system in the generation of resistance to directed therapies and support the potential benefit of MAPK inhibition in combination with immunotherapies. Both soluble and EV-associated NKG2D-ligands, generally decreased in BRAF-mutant melanoma cell supernatants after MAPKi in vitro, replicating cell surface expression. Because potential NKG2D-ligand fluctuation during MAPKi treatment could have different consequences for the immune response, a pilot study to measure NKG2D-ligand variation in plasma or serum from metastatic melanoma patients, at different time points during MAPKi treatment, was performed. Not all NKG2D-ligands were equally detected. Further, EV detection did not parallel soluble protein. Altogether, our data confirm the heterogeneity between melanoma lesions, and suggest testing several NKG2D-ligands and other melanoma antigens in serum, both as soluble or vesicle-released proteins, to help classifying immune competence of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.