Background Preeclampsia is a multifactorial cardiovascular disorder of pregnancy. If left untreated, it can lead to severe maternal and fetal outcomes. Hence, timely diagnosis and management of preeclampsia are extremely important. Biomarkers of oxidative stress are associated with the pathogenesis of preeclampsia and therefore could be indicative of evolving preeclampsia and utilized for timely diagnosis. In this study, we conducted a systematic review and meta-analysis to determine the most reliable oxidative stress biomarkers in preeclampsia, based on their diagnostic sensitivities and specificities as well as their positive and negative predictive values. Methods A systematic search using PubMed, ScienceDirect, ResearchGate, and PLOS databases (1900 to March 2021) identified nine relevant studies including a total of 343 women with preeclampsia and 354 normotensive controls. Results Ischemia-modified albumin (IMA), uric acid (UA), and malondialdehyde (MDA) were associated with 3.38 (95% CI 2.23, 4.53), 3.05 (95% CI 2.39, 3.71), and 2.37 (95% CI 1.03, 3.70) odds ratios for preeclampsia diagnosis, respectively. The IMA showed the most promising diagnostic potential with the positive predictive ratio (PPV) of 0.852 (95% CI 0.728, 0.929) and negative predictive ratio (NPV) of 0.811 (95% CI 0.683, 0.890) for preeclampsia. Minor between-study heterogeneity was reported for these biomarkers (Higgins’ I2 = 0–15.879%). Conclusions This systematic review and meta-analysis identified IMA, UA, and MDA as the most promising oxidative stress biomarkers associated with established preeclampsia. IMA as a biomarker of tissue damage exhibited the best diagnostic test accuracy. Thus, these oxidative stress biomarkers should be further explored in larger cohorts for preeclampsia diagnosis. Graphical Abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.