A high concordance was found between sonR and the cardiac ultrasound in the timings of aortic and mitral valve closures and in the estimation of systolic and diastolic intervals durations. These observations suggest that sonR could be used to monitor cardiac function and adaptively optimize CRT systems.
Despite the low long-term incidence of high-degree atrioventricular (AV) block and the known negative effects of ventricular pacing, programming of the AAI mode in patients with sinus node dysfunction (SND) remains exceptional. A new pacing mode was, therefore, designed to combine the advantages of AAI with the safety of DDD pacing. AAIsafeR behaves like the AAI mode in absence of AV block. First- and second-degree AV blocks are tolerated up to a predetermined, programmable limit, and conversion to DDD takes place in case of high-degree AV block. From DDD, the device may switch back to AAI, provided AV conduction has returned. The safety of AAIsafeR was examined in 43 recipients (70 +/- 12-year old, 24 men) of dual chamber pacemakers implanted for SND or paroxysmal AV block. All patients underwent 24-hour ambulatory electrocardiographic recordings before hospital discharge and at 1 month of follow-up with the AAIsafeR mode activated. No AAIsafeR-related adverse event was observed. At 1 month, the device was functioning in AAIsafeR in 28 patients (65%), and the mean rate of ventricular pacing was 0.2%+/- 0.4%. Appropriate switches to DDD occurred in 15 patients (35%) for frequent, unexpected AV block. AAIsafeR mode was safe and preserved ventricular function during paroxysmal AV block, while maintaining a very low rate of ventricular pacing. The performance of this new pacing mode in the prevention of atrial fibrillation will be examined in a large, controlled study.
AAIsafeR2 mode seems to be safe and reliable in patients with infrequent slowing or pauses in ventricular activity, while maintaining ventricular pacing below 1%.
Abstract-Previous studies have shown that cardiac microacceleration signals, recorded either cutaneously, or embedded into the tip of an endocardial pacing lead, provide meaningful information to characterize the cardiac mechanical function. This information may be useful to personalize and optimize the cardiac resynchronization therapy, delivered by a biventricular pacemaker, for patients suffering from chronic heart failure. The present paper focuses on the improvement of a previously proposed method for the estimation of the systole period from a signal acquired with a cardiac micro-accelerometer (SonR sensor, Sorin CRM SAS, France). We propose an optimal algorithm switching approach, to dynamically select the best configuration of the estimation method, as a function of different control variables, such as signal-to-noise ratio or heart rate. This method was evaluated on a database containing recordings from 31 patients suffering from chronic heart failure and implanted with a biventricular pacemaker, for which various cardiac pacing configurations were tested. Ultrasound measurements of the systole period were used as a reference and the improved method was compared with the original estimator. A reduction of 11% on the absolute estimation error was obtained for the systole period with the proposed algorithm switching approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.