Android-HCLS in both adults and adolescents reduced nocturnal hypoglycemia and, in adults, improved overnight time in target range and treatment satisfaction compared with SAP-LGS.
This study provides relevant insights for implementation of closed-loop in the real world. For people with diabetes who are less familiar with technology, remote monitoring for the first few days may provide reassurance, strengthen their trust/skills, and make closed-loop an acceptable option for more people with type 1 diabetes.
Objective: There is increasing use of open-source artificial pancreas systems (APS) in the management of Type 1 diabetes. Our aim was to assess the safety and efficacy of the automated insulin delivery system AndroidAPS (AAPS), compared with stand-alone pump therapy in people with type 1 diabetes. The primary outcome was the difference in the percentage of time in range (TIR, 70-180 mg/dL). Secondary aims included mean sensor glucose value and percent continuous glucose monitor (CGM) time below range (TBR, <70 mg/dL). Research Design and Methods: This open-label single-center randomized crossover study (ANZCTR, Australian New Zealand clinical trial registry, ANZCTR-ACTRN12620001191987) comprised 20 participants with type 1 diabetes on established pump therapy, assigned to either stand-alone insulin pump therapy or the open-source AAPS hybrid closed-loop system for four weeks, with crossover to the alternate arm for the following four weeks. The CGM outcome parameters were measured by seven-day CGM at baseline and the final week of each four-week study arm. Results: Twenty participants were recruited (60% women), aged 45.8 ± 15.9 years, with mean diabetes duration of 23.9 ± 13.2 years, baseline glycated hemoglobin (HbA1c) 7.5% ± 0.5% (58 ± 6 mmol/mol) and mean TIR 62.3% ± 12.9%. The change in TIR from baseline for AAPS compared with stand-alone pump therapy was 18.6% (11.4-25.9), ( P < .001), TIR 76.6% ± 11.7%, 58.0% ± 15.6%, for AAPS and stand-alone pump, respectively. Time glucose <54 mg/dL was not increased (mean = −2.0%, P = .191). No serious adverse events or episodes of severe hypoglycemia were recorded. Conclusions: This clinical trial of the open-source AAPS hybrid closed-loop system performed in an at-home setting demonstrated comparable safety to stand-alone pump therapy. The glycemic outcomes of AAPS were superior with improved TIR, and there was no significant difference in TBR compared with stand-alone pump therapy.
Electrochemical redundancy enhances glucose sensor accuracy and display time compared with each individual sensing element alone. ERS performance compares favorably with 'best-in-class' of non-redundant sensors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.