Using a microfabricated porous media mimic platform, we investigated how fluid flow influences the formation of filamentous structures, known as streamers, between porous media structures. We demonstrate how hydrodynamics govern the formation, morphology and the distribution of these biofilm streamers in the device. Our work establishes that, under favorable hydrodynamic conditions, streamers can often act as precursors to mature microbial structures found in complex geometries, such as those involved in porous media.
Nanopillars have been shown to mechanically damage bacteria, suggesting a promising strategy for future antibacterial surfaces. However, the mechanisms underlying this phenomena remain unclear, which ultimately limits translational potential toward real-world applications. Using real-time and end-point analysis techniques, we demonstrate that in contrast to initial expectations, bacteria on multiple hydrophilic “mechano-bactericidal” surfaces remained viable unless exposed to a moving air–liquid interface, which caused considerable cell death. Reasoning that normal forces arising from surface tension may underlie this mechano-bactericidal activity, we developed computational and experimental models to estimate, manipulate, and recreate the impact of these forces. Our experiments together demonstrate that a critical level of external force acting on cells attached to nanopillar surfaces can rapidly deform and rupture bacteria. These studies provide fundamental physical insight into how nanopillar surfaces can serve as effective antibacterial materials and suggest use-conditions under which such nanotechnology approaches may provide practical value.
Sutures pervade surgeries, but their performance is limited by the mechanical mismatch with tissues and the lack of advanced functionality. Existing modification strategies result in either deterioration of suture’s bulk properties or a weak coating susceptible to rupture or delamination. Inspired by tendon endotenon sheath, we report a versatile strategy to functionalize fiber-based devices such as sutures. This strategy seamlessly unites surgical sutures, tough gel sheath, and various functional materials. Robust modification is demonstrated with strong interfacial adhesion (>2000 J m−2). The surface stiffness, friction, and drag of the suture when interfacing with tissues can be markedly reduced, without compromising the tensile strength. Versatile functionalization of the suture for infection prevention, wound monitoring, drug delivery, and near-infrared imaging is then presented. This platform technology is applicable to other fiber-based devices and foreseen to affect broad technological areas ranging from wound management to smart textiles.
In this study, a carboxyl-modified cellulosic hydrogel was developed as the base material for wound dressings. ε-poly-l-lysine, a natural polyamide, was then covalently linked to the hydrogel through a bioconjugation reaction, which was confirmed by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR). The antibacterial efficacy of the hydrogel was tested against two model bacteria, Staphylococcus aureus and Pseudomonas aeruginosa, two of the most commonly found bacteria in wound infections. Bacterial viability and biofilm formation after exposure of bacteria to the hydrogels were used as efficacy indicators. Live/Dead assay was used to measure the number of compromised bacteria using a confocal laser scanning microscope. The results show that the antibacterial hydrogel was able to kill approximately 99% of the exposed bacteria after 3 h of exposure. In addition, NIH/3T3 fibroblasts were used to study the biocompatibility of the developed hydrogels. Water-soluble tetrazolium salt (WST)-1 assay was used to measure the metabolic activity of the cells and Live/Dead assay was used to measure the viability of the cells after 24, 48, and 72 h. The developed antibacterial hydrogels are light weight, have a high water-uptake capacity, and show high biocompatibility with the model mammalian cells, which make them a promising candidate to be used for wound dressing applications.
Non-compressible hemorrhage is an unmet clinical challenge that accounts for high mortality in trauma. Rapid pressurized blood flows under hemorrhage impair the function and integrity of hemostatic agents and the adhesion of bioadhesive sealants. Here, we report the design and performance of bioinspired microstructured bioadhesives, formed with a macroporous tough xerogel infused with functional liquids. The xerogel can rapidly absorb interfacial fluids such as whole blood and promote blood clotting, while the infused liquids facilitate interfacial bonding, sealing, and antibacterial function. Their synergy enables the bioadhesives to form tough adhesion on ex vivo human and porcine tissues and diverse engineered surfaces without the need for compression, as well as on-demand instant removal and storage stability. We demonstrate a significantly improved hemostatic efficacy and biocompatibility in rats and pigs compared to non-structured counterparts and commercial products. This work opens new avenues for the development of bioadhesives and hemostatic sealants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.