An investigation is performed for natural convection of air in a three dimensional inclined annulus enclosure. The annulus material is made of silica aerogel/glass fiber composite materials. The annulus enclosure is filled with silica sand between two inclined concentric cylinders with fins attached to the inner cylinder. Constant walls temperature boundary conditions are considered under steady state condition. The parameters affected on the system are modified Rayleigh number (10 ≤Ra * ≤ 500) and the annulus inclination angle δ (0 o , 30 o , 45 o , 60 o and 90 o ). The effect of fibres filler in composite material is investigated and two values of effective thermal conductivity are performed: the minimum and the maximum values considering the fiber alignment effect. The results showed insignificant effect of the inclination angle on the average Nusselt number for the low values of Ra * . The average Nu number increases with an increase in modified Rayleigh number and decrease with the increase of δ for high values of Ra * . The deviation between the average Nu for the maximization and minimization of the thermal conductivity is equal to 2.26% for δ=90 o (horizontal annulus) and 0.46% for δ=0 o (vertical annulus). A correlation for the average Nusselt number in terms of Ra * and δ, has been developed for the outer cold cylinder and for the two cases of maximization and minimization of thermal conductivity.
This paper presents a numerical investigation for natural convection of air in a three dimensional inclined annulus enclosure. This study wills exam the effect of radius ratio of an annulus made from graphite/epoxy laminated composite material on heat transfer taking two types of optimization of effective thermal conductivity in consideration: minimization and maximization of thermal conductivity. The annulus enclosure is filled with porous media between two concentric cylinders with 12 fins attached to the inner cylinder. Two cases are taken for the inclination angle of the annulus: horizontal and vertical annulus. The system is under steady state condition and constant walls temperature boundary condition. The parameters affected on the system are modified Rayleigh number (10 ≤Ra * ≤ 500), the annulus inclination angle δ (0 o and 90 o ) and the radius ratio Rr= (RI/RO)=0.2, 0.3, 0.4 and 0.5.For all parameters, results showed that Nusselt number decrease with the decrease of the radius ratio Rr (which means larger gap) for the outer cold cylinder. the average Nu number increases with an increase in modified Rayleigh number and decrease with the increase of δ for high values of Ra * , but hardly affected by δ for low values of Ra * . The deviation between the average Nu for the maximization and minimization of the thermal conductivity is equal to 5.1% for horizontal annulus δ=0 o and 10% for vertical annulus δ=90 o . Local Nu increases with the length of the cylinder and the effect of the fins attached to the inner cylinder is more significant for the horizontal cylinder because of its hindering effect. A correlation for the average Nusselt number in terms of Ra * and δ, has been developed for the outer cold cylinder.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.