Stentless aortic bioprostheses have been successfully used for over a decade. The 3f bioprosthesis is a new equine pericardial stentless valve, unique in its tubular design, preserving the native aortic sinuses post-implant. Forty-six consecutive aortic valve replacements with the 3f bioprosthesis were performed between June 2003 and January 2005. The patients were prospectively assessed and echocardiography was performed at 6 months, 12 months, and annually thereafter. The median follow-up was 2.1 + or - 0.9 years. There was one early and 4 late deaths; none were valve-related. The 2-year mean transvalvular gradient was 8.8 + or - 3.8 mm Hg, the mean echocardiographic aortic regurgitation grade was 0.4 + or - 0.7 (grade 1 being trivial). Echocardiographic sizing of the aortic annulus before surgery accurately predicted prosthesis size. The 3f bioprosthesis is easy to implant. Early clinical results are favorable, with hemodynamic profiles consistent with those of other stentless prostheses. Longer follow-up is required to confirm its durability.
We report three cases of symptomatic stenosis of the great vessels or supra-aortic trunks successfully treated surgically with aorto-subclavian and aorto-innominate bypass. Two were performed via manubriotomy and a third case via standard median sternotomy because of concomitant coronary revascularisation. There was complete symptomatic relief on follow-up, and radiological imaging confirmed good flow in the grafts and post-stenotic arteries.
Recently reported acute complications associated with biological tissue sealants in cardiac surgery have prompted the use of more rapidly polymerizing cyanoacrylate compounds. We describe, however, that de-airing after aortic valve replacement (AVR) represents a critical window during which these newer agents can lead to potentially life-threatening glue "thrombus" formation.
Type A aortic dissection is a life-threatening condition with a wide range of clinical manifestations. Dissection can sometimes mimic an acute myocardial infarction due to similar presenting symptoms and initial clinical investigations. We report the case of a 52-year-old male who presented with an inferior ST-segment elevation myocardial infarction with two drug-eluting stents inserted as a stabilizing intervention prior to surgical repair of an acute aortic dissection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.