The manufacture of kitchen and bath countertops in Israel is based mainly on artificial stone that contains 93% silica as natural quartz, and ∼3500 workers are involved in cutting and processing it. Artificial stone produces high concentrations of silica dust. Exposure to crystalline silica may cause silicosis, an irreversible lung disease. Our aim was to screen exposed workers by quantitative biometric monitoring of functional and inflammatory parameters.68 exposed artificial stone workers were compared to 48 nonexposed individuals (controls). Exposed workers filled in questionnaires, and all participants underwent pulmonary function tests and induced sputum analyses. Silica was quantitated by a Niton XL3 X-ray fluorescence spectrometer.Pulmonary function test results of exposed workers were significantly lower and induced sputa showed significantly higher neutrophilic inflammation compared to controls; both processes were slowed down by the use of protective measures in the workplace. Particle size distribution in induced sputum samples of exposed workers was similar to that of artificial stone dust, which contained aluminium, zirconium and titanium in addition to silica.In conclusion, the quantitation of biometric parameters is useful for monitoring workers exposed to artificial stone in order to avoid deterioration over time.
ObjectiveArtificial stone dust (ASD) contains high levels of ultrafine particles (UFP <1 µm) which penetrate deeply into the lungs. This study aimed to demonstrate the direct effect of UFP in the lungs of ASD-exposed workers on functional inflammatory and imaging parameters.Methods68 workers with up to 20 years of ASD exposure at the workplace were recruited from small enterprises throughout the country and compared with 48 non-exposed individuals. Pulmonary function test (PFT), CT, induced sputum (IS) and cytokine analyses were performed by conventional methods. The CT scans were evaluated for features indicative of silicosis in three zones of each lung. UFP were quantitated by the NanoSight LM20 system (NanoSight, Salisbury) using the Nanoparticle Tracking Analysis. Interleukin (IL)-6, IL-8 and tumour necrosis factor alpha (TNF-α) levels were measured by Luminex (R&D Systems).ResultsThirty-four patients had CT scores between 0 and 42, and 29 of them were diagnosed with silicosis. Content of the UFP retrieved from IS supernatants correlated negatively with the PFT results (total lung capacity r=−0.347, p=0.011; forced expiratory volume in 1 s r=−0.299, p=0.046; diffusion lung carbon monoxide in a single breath r=−0.425, p=0.004) and with the CT score (r=0.378, p=0.023), and with the inflammatory cytokines IL-8 (r=0.336, p=0.024), IL-6 (r=0.294, p=0.065) and TNF-α (r=0.409, p=0.007). Raw material of ASD was left to sedimentate in water for <15 min, and 50% of the floating particles were UFP. A cut-off of 8×106 UFP/mL in IS samples had a sensitivity of 77% to predict pulmonary disease.ConclusionsThis is the first demonstration of an association between UFP-related decreased PFT results, worsening of CT findings and elevation of inflammatory cytokines, which may be attributed to high-dose inhalation of UFP of ASD at the workplace.
BackgroundPulmonary function is often affected by the inhalation of metal particles. The resulting pathology might trigger various lung diseases, e.g., parenchymal lung fibrosis and granulomatous lung disorders. We previously demonstrated that 6 % of tissue-proven sarcoid patients had a positive beryllium lymphocyte proliferation test (BeLPT), thus correcting the diagnosis to chronic beryllium disease. The aim of this study was to examine if MEmory Lymphocyte Immnuno Stimulation Assay (MELISA®), currently used for non-pulmonary diseases, can identify metals other than beryllium that can also trigger sensitization and induce granulomatous disease.MethodsThis pilot study included 13 sarcoid-like patients who underwent MELISA®. Eleven patients also underwent BeLPT. Biopsy samples were tested for metal content by scanning electron microscope. Eleven study patients had been exposed to metals at the workplace and 2 had silicone implants.ResultsTwo patients who had undergone BeLPT were positive for beryllium. MELISA® detected 9 patients (9/13, 69 %) who were positive for at least one of the tested metals: 4 reacted positively to nickel, 4 to titanium, 2 to chromium, 2 to beryllium, 2 to silica, and one each to palladium, mercury and lead.ConclusionIt is proposed that MELISA® can be exploited to also identify specific sensitization in individuals exposed to inhaled particles from a variety of metals.
Ultrafine particles (UFP) have been postulated to significantly contribute to the adverse health effects associated with exposure to particulate matter (PM). Due to their extremely small size (aerodynamic diameter <100 nm), UFP are able to deposit deep within the lung after inhalation and evade many mechanisms responsible for the clearance of larger particles. There is a lack of biologically relevant personal exposure metrics for exposure to occupational- and environmental-related micro- and nano-sized PM. The aim of the present study is to assess UFP in induced sputum (IS) and exhaled breath condensate (EBC) as possible biomarkers for assessing lung function impairment. Sputum induction and EBC testing were performed by conventional methods. UFP particles were assessed with the NanoSight LM20 (NanoSight Ltd, London, UK). The subjects included 35 exposed and 25 non-exposed workers. There were no group differences in pulmonary function test results and differential cell counts, but 63.6% of the exposed subjects had a higher percentage of neutrophils (OR3.28 p = 0.03) compared to the non-exposed subjects. The exposed subjects had higher percentages of UFP between 10 and 50 nm (69.45 ± 18.70 vs 60.11 ± 17.52 for the non-exposed group, p = 0.004). No differences were found in the IS samples. Years of exposure correlated positively to UFP content (r = 0.342 p = 0.01) and macrophage content (r = −0.327 p = 0.03). The percentage of small fraction of UFP in EBC, but not IS, is higher in exposed workers, and EBC may be a sensitive biomarker to assess exposure to nanoparticles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.