Background: The introduction of the vaccination against SARS-CoV-2 infection creates the need for precise tools for the quality control of vaccination procedures, detection of poor humoral response, and estimation of the achieved protection against the disease. Thus, the study aimed to compare the results of the anti-SARS-CoV-2 tests to evaluate the application of the WHO standard unitage (the binding antibody units; BAU/mL) for a measurement of response to the vaccination. Methods: Patients undergoing vaccination against SARS-CoV-2 with Pfizer/BioNTech BNT162b2 (BNT162b2) (n = 79), referred for SARS-CoV-2 antibody measurement prior to vaccination and 21 days after dose 1, and 8, 14, and 30 days after dose 2 were included. The sera were tested with three assays: Elecsys SARS-CoV-2 S (Roche), LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin), and SARS-CoV-2 IgG II Quant (Abbott). Results: The three assays showed varying correlations at different time points in the study. The overall agreement for all samples was moderate to high (ρ = 0.663–0.902). We observed the most uniform agreement for the day of dose 2 (ρ = 0.775–0.825), while it was least consistent for day 8 (ρ = −0.131–0.693) and 14 (ρ = −0.247–0.603) after dose 2. The dynamics of changes of the SARS-CoV-2 antibody levels in patients without history of prior SARS-CoV-2 infection appears homogenous based on the Roche results, more heterogenous when considering the DiaSorin results, and in between for the Abbott results. Conclusions: The results highlight the need for further work on the international standard of measurement of SARS-CoV-2 Ig, especially in the era of vaccination. The serological assays can be useful to detect IgG/IgM antibodies to assess the response to the vaccination. However, they cannot be used interchangeably. In terms of the evaluation of the immune response to the BNT162b2 vaccine, Roche and Abbott kits appear to be more useful.
A retrospective case control study was undertaken at the molecular biology department of a private center for reproductive medicine in order to determine whether any correlation exists between mitochondrial DNA (mtDNA) content of cleavage-stage preimplantation embryos and their developmental potential. A total of 69 couples underwent IVF treatment (averaged women age: 36.5, SD 4.9) and produced a total of 314 embryos. A single blastomere was biopsied from each embryo at the cleavage stage (day-3 post-fertilization) subjected to low-pass next generation sequencing (NGS), for the purpose of detecting aneuploidy. For each sample, the number of mtDNA reads obtained after analysis using NGS was divided by the number of reads attributable to the nuclear genome. The mtDNA copy number amount was found to be higher in aneuploid embryos than in those that were euploid (mean mtDNA ratio ± SD: 6.3 ± 7.5 versus 7.1 ± 5.8, p < 0.004; U Mann–Whitney test), whereas no statistically significant differences in mtDNA content were seen in relation to embryo morphology (6.6 ± 4.8 vs. 8.5 ± 13.6, p 0.09), sex (6.6 ± 4.1 vs. 6.2 ± 6.8, p 0.16), maternal age (6.9 ± 7.8 vs. 6.7 ± 4.5, p 0.14) or its ability to implant (7.4 ± 6.6 vs. 5.1 ± 4.6, p 0.18). The mtDNA content cannot serve as a useful biomarker at this point in development. However, further studies investigating both quantitative and qualitative aspects of mtDNA are still required to fully evaluate the relationship between mitochondrial DNA and human reproduction.
Mitochondria are well known as ‘the powerhouses of the cell’. Indeed, their major role is cellular energy production driven by both mitochondrial and nuclear DNA. Such a feature makes these organelles essential for successful fertilisation and proper embryo implantation and development. Generally, mitochondrial DNA is exclusively maternally inherited; oocyte’s mitochondrial DNA level is crucial to provide sufficient ATP content for the developing embryo until the blastocyst stage of development. Additionally, human fertility and early embryogenesis may be affected by either point mutations or deletions in mitochondrial DNA. It was suggested that their accumulation may be associated with ovarian ageing. If so, is mitochondrial dysfunction the cause or consequence of ovarian ageing? Moreover, such an obvious relationship of mitochondria and mitochondrial genome with human fertility and early embryo development gives the field of mitochondrial research a great potential to be of use in clinical application. However, even now, the area of assessing and improving DNA quantity and function in reproductive medicine drives many questions and uncertainties. This review summarises the role of mitochondria and mitochondrial DNA in human reproduction and gives an insight into the utility of their clinical use.
BackgroundThe introduction of vaccination against SARS-CoV-2 infection needs precise instruments for quality control of vaccination procedure, detection of poor immunological response and estimation of the achieved protection against the disease but also against infection and being infective.ObjectiveTo compare new automated SARS-CoV 2 Ig assay performance characteristics from the automated Elecsys SARS-CoV-2 S (Roche) with the new LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin) assay and their compatibility with WHO International Standard for anti-SARS-CoV-2 immunoglobulin. In the context of the mass vaccination programs, we undertook the investigation of clinical utility of the two new automated assays by analyzing results in samples collected at specified time points relative to the vaccination time.DesignProspective assay evaluation.PatientsMedical staff undergoing vaccination with BioNTech/Pfizer Comirnaty vaccine between January and March 2021 (n = 79) and referred for serum antiSARS-CoV 2 Ig testing prior to vaccination, 21 days after the first dose, and 8, 14 and 30 days after the second dose. Main Outcome Measure(s): Serum antibody levels measured with Roche and DiaSorin assays.ResultsIntra-assay imprecision was low with DiaSorin at 3.46%; and Roche at 2.5%. The Passing-Bablok regression equation for all tested samples was y (DiaSorin) = 184.61 + (1.03 x Roche) and the correlation between the assays (r=0.587; p < 0.0001).ConclusionsThe novel automated assays exhibit strong concordance in calibration, with assay-specific interpretation required for routine clinical use. These results highlight the need for further work on the international standard of measurement of SARS-CoV 2 Ig especially in era of vaccination. The serological assays can be useful to detect IgG/IgM antibodies, to assess the degree of immunization, to trace the contacts, and to support the decision to readmit people to work or vaccinate them again. However, the values generated by both assays can be markedly different, and assay-specific and personalized interpretation is required.
A nonsense mutation, p.Q548X, in the BLM gene has recently been associated with an increased risk for breast cancer. In the present work, we investigated the prevalence of this Slavic founder mutation in 2,561 ovarian cancer cases from Russia, Belarus, Poland, Lithuania or Germany and compared its frequency with 6,205 ethnically matched healthy female controls. The p.Q548X allele was present in nine ovarian cancer patients of Slavic ancestry (0.5 %; including one case with concurrent BRCA1 mutation). The mutation was not significantly more frequent in cases than in controls (Mantel-Haenszel OR 1.14, 95 % CI 0.49; 2.67). Ovarian tumours in p.Q548X carriers were mainly of the serous subtype, and there was little evidence for an early age at diagnosis or pronounced family history of cancer. These findings indicate that the BLM p.Q548X mutation is not a strong risk factor for ovarian cancer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.