Both devices served as effective conduits for fiberoptic-guided tracheal intubation. The limitation of the narrower proximal airway tube of the size 1.5 Aura-i should be considered if cuffed tracheal tubes are to be utilized.
SummaryWe conducted a randomised trial in 100 children in order to compare the clinical performance of the Ambu â AuraGain TM and the LMA â Supreme * for airway maintenance during mechanical ventilation. The primary outcomes were initial and 10-min airway leak pressures. Ease, time and success rates for device and gastric tube insertion, fibreoptic grades of view, airway quality during anaesthetic maintenance, and complications were also assessed. 16-26 [12-40]) cmH 2 O, p = 0.08, respectively. Ease, time and success rates for device placement, gastric tube insertion and complications were also not significantly different. Children receiving the LMA Supreme required more airway manouevers (7 vs 1 patient, p = 0.06) to maintain a patent airway. Our results suggest that the Ambu AuraGain may be a useful alternative to the LMA Supreme, as demonstrated by comparable overall clinical performance in children.
SummaryWe conducted a randomised controlled trial comparing the laryngeal mask airway Supreme TM with the laryngeal mask airway Unique TM in children. Fifty children presenting for elective surgery were randomly assigned to receive either the laryngeal mask airway Supreme or laryngeal mask airway Unique. The outcomes measured were airway leak pressure, ease and time for insertion, insertion success rate, fibreoptic examination, incidence of gastric insufflation, ease of gastric tube placement through the laryngeal mask airway Supreme, quality of airway during anaesthetic maintenance and complications. Median (IQR [range]) time to successful device placement was shorter with the laryngeal mask airway Unique, 14.5 [13.5-16.3 (10.0-23.6)] s than with the laryngeal mask airway Supreme,
In infants and children, when a single-use supraglottic device with gastric access capabilities is required, the i-gel demonstrated higher airway leak pressures and can be a useful alternative to the Supreme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.