Complete transection of the common femoral artery is more frequent after penetrating injuries than after blunt trauma, with most of the cases occurring in combination with fractures. Contusion from a bicycle handlebar is a rare form of injury to the femoral vessels. Hereby, we present a case of complete common femoral artery transection caused by a direct bicycle handlebar trauma. The patient suffered severe hypovolemia during his transfer to the Emergency room. He required an emergency intervention and a bypass reconstruction.
Objective Data in literature suggest iliac artery dilatation and endograft retraction as complications after endovascular aneurysm repair. However, mainly older generation endografts were included. Therefore, we sought to evaluate the distal sealing zone chronological changes after endovascular aneurysm repair with newer generation stent-grafts. Methods Clinical and radiological data of patients with abdominal aortic aneurysms treated with endovascular aneurysm repair between January 2010 and December 2013 were reviewed. Measurements were made using volumetric reconstructions in the first and last available computed tomography angiography. Endpoints of the study were the presence of iliac dilatation and retraction of the endograft. Association with distal oversizing and sealing length was analyzed. Results Consecutive patients with a total of 52 common iliac arteries were included in the study (mean age 74.9 ± 6.8 years, four women (7.7%)). The mean follow-up was 3.1 years. The mean iliac diameter increased from 15.5 to 17.1 mm ( p < .001) in the first control computed tomography angiography and to 18.7 mm ( p < .001) in the last available computed tomography angiography. No endograft (Endurant by Medtronic (24/52; 46%), Excluder de Gore (23/52; 44%), Zenith by Cook (5/52; 9%)) was associated with dilatation ( p = .066) or iliac retraction ( p = .591). Two type Ib endoleaks were found (3.8%) and successfully treated with distal graft extension. An iliac branch retraction of ≥5 mm was identified in seven cases (13%). Iliac arteries treated with limbs of ≥24 mm in diameter dilated significantly more than the rest of limbs (5.37 mm versus 3.12 mm; p = .022). In the last available imaging, iliac dilatation was ≥20% in 28 cases (53.8%) and had exceeded the diameter of the implanted endograft in 20 cases (38.4%). Iliac dilatation (OR 15.11 per mm, p = .025) was identified as a risk factor for retraction ≥5 mm. Conclusion Iliac dilatation and endograft limb retraction are common findings after endovascular aneurysm repair despite the use of new generation endografts. Optimizing the iliac sealing length and meticulous computed tomography angiography surveillance are recommended especially in case of use ≥24 mm iliac stent-grafts to prevent possible complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.