Teeth were best viewed on periapical radiographs except maxillary second and third molars, which were better viewed in orthopantomograms. Orthopantomograms on screen were scorable more often than when on printed images. Apical periodontitis was scored more often on paper than on screen, and more often on screen than in periapical radiographs.
Introduction and hypothesisThe objective was to identify the best parameter (pubis-cervix measurement, pubis-uterine fundus measurement or pubis-pouch of Douglas measurement) on transperineal ultrasound, based on the difference between measurements taken at rest and with the Valsalva maneuver, for presurgical differential diagnosis between uterine prolapse (UP) and cervical elongation (CE) without UP. Methods A prospective observational study of 60 consecutively recruited patients who underwent corrective surgery of the middle compartment (UP or CE without UP). A transperineal ultrasound was performed, and the descent of the pelvic organ was measured in relation to the posteroinferior margin of the pubis in the midsagittal plane, referencing the uterine fundus, pouch of Douglas and the cervix at rest and with the Valsalva test. Results Receiver operating characteristic (ROC) curves were constructed for the three evaluated measures, based on the difference between rest and Valsalva, for the diagnosis of UP. For the pubis-cervix distance, an area under the curve (AUC) of 0.59 was obtained; for the pubis-uterine fundus distance, the AUC was 0.81; and for the pubis-pouch of Douglas distance, the AUC was 0.69. Based on the best AUC (the difference in the pubis-uterine fundus distance at rest and with the Valsalva maneuver), a cut-off point of 15 mm was established for the diagnosis of UP (sensitivity: 75%; specificity: 95%; positive predictive value: 86%; and negative predictive value: 89%). Conclusion A difference of ≥15 mm in the pubis-uterine fundus distance at rest and with the Valsalva maneuver is useful for differentiating UP from CE without UP by ultrasound.
Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability).
Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method.
Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive measurements were registered with each transducer.
Results: Average ISQ varied from 72.43 to 72.60 and 73.26 in the first, second and third measurements, respectively with the SamrtPeg I and from 72.98 to 73.26 and 73.74 in the first, second and third measurements, respectively with the SamrtPeg II . Exactly equal values were observed in 10.43 and 12.1% of the cases with Smart-Pegs I and II, respectively. The intraclass correlation coefficient was 0.96 and 0.96 for Smart Pegs I and II, respectively. Repeatability and reproducibility was 0.97 for both Smart-Pegs I and II.
Conclusions: The RFA system contributed by Osstell Mentor® renders almost perfect reproducibility and repeatability, as proven by statistical analysis carried out by means of ICC with 95% confidence level. This instrument contributes highly reliable RFA measurements in dental implants.
Key words:Dental implants, RFA, ISQ, implant stability, Osstell.
We have observed that the presence of an AoP with pushing <105°, a PD <25 mm, a "head-down" direction and a >45° MLA are very unfavorable ITU parameters which can be used to identify cases of high risk of fetal extraction failure in vacuum-assisted deliveries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.