Recently, a number of theoretical and experimental studies have been performed to understand the effect of nanoparticles on thermal properties and heat transfer performance but there is a lack regarding their corrosion properties. In this work, an extended corrosion characterization (at central tower plant storage temperature (565ºC)) has been carried out in two different grades of solar salt (industrial and refined purity) doped with the addition of 1 wt% Al 2 O 3 nanoparticles or 1 wt% SiO 2 nanoparticles. Corrosion rates were determined in commercial stainless steel commonly used in CSP technology (347SS) by gravimetric tests, measuring the weight gain during 1000 hours, identifying the corrosion products by Scanning Electron Microscopy (SEM) and X-Ray Diffraction (XRD). The lowest corrosion rate (0.007 mm/year) was obtained in the refined solar salt with the addition of 1 wt% Al 2 O 3 nanoparticles. A protective layer was formed in the steel-salt interphase, identified through XRD as Al 2 O 3 .Additionally, hematite (Fe 2 O 3 ) and magnetite (Fe 3 O 4 ) were obtained as unprotective corrosion products throughout the test carried out with or without nanoparticles. In addition, the presence of impurities on the salts generated some stable compounds, as magnesium ferrite (MgFe 2 O 4 ) .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.