Nineteen scorers from seven Cuban laboratories participated in this slide exercise designed to test the influence of the scorer on the accuracy, sensitivity and variability of the comet assay when a visual method of DNA damage evaluation is used. The assay was performed using human lymphocytes from a single donor exposed in vitro for 5 min at 0 degrees C to doses of 0, 5, 10, 25, 50, 100 and 200 microM of hydrogen peroxide. Each participant scored the same set of 14 coded slides with silver stained comets. The comets were classified visually into five categories according to the appearance resulting from the relative proportion of DNA in the tail. The extent of DNA damage was expressed in arbitrary units. At zero dose the median values of 12 scorers out of 19 were included between the values of the overall 25 and 75 per thousand. This proportion remains practically the same as the dose increases. The lowest dose detected by this method for the majority of scorers (11) was 10 microM. The coefficient of variation at the control dose was the highest (median value 26%), progressively declined to 20%, and starting from 25 microM, values are around 10%. The results of the exercise show the reliability of the silver staining and visual scoring for the comet method.
Well-defined protocols and quality management standards are indispensable for biological dosimetry laboratories. Participation in periodic proficiency testing by interlaboratory comparisons is also required. This harmonization is essential if a cooperative network is used to respond to a mass casualty event. Here we present an international intercomparison based on dicentric chromosome analysis for dose assessment performed in the framework of the IAEA Regional Latin American RLA/9/054 Project. The exercise involved 14 laboratories, 8 from Latin America and 6 from Europe. The performance of each laboratory and the reproducibility of the exercise were evaluated using robust methods described in ISO standards. The study was based on the analysis of slides from samples irradiated with 0.75 (DI) and 2.5 Gy (DII). Laboratories were required to score the frequency of dicentrics and convert them to estimated doses, using their own dose-effect curves, after the analysis of 50 or 100 cells (triage mode) and after conventional scoring of 500 cells or 100 dicentrics. In the conntional scoring, at both doses, all reported frequencies were considered as satisfactory, and two reported doses were considered as questionable. The analysis of the data dispersion among the dicentric frequencies and among doses indicated a better reproducibility for estimated doses (15.6% for DI and 8.8% for DII) than for frequencies (24.4% for DI and 11.4% for DII), expressed by the coefficient of variation. In the two triage modes, although robust analysis classified some reported frequencies or doses as unsatisfactory or questionable, all estimated doses were in agreement with the accepted error of ±0.5 Gy. However, at the DI dose and for 50 scored cells, 5 out of the 14 reported confidence intervals that included zero dose and could be interpreted as false negatives. This improved with 100 cells, where only one confidence interval included zero dose. At the DII dose, all estimations fell within ±0.5 Gy of the reference dose interval. The results obtained in this triage exercise indicated that it is better to report doses than frequencies. Overall, in both triage and conventional scoring modes, the laboratory performances were satisfactory for mutual cooperation purposes. These data reinforce the view that collaborative networking in the case of a mass casualty event can be successful.
In case of an accidental overexposure to ionizing radiation where the dose received by the victim is over 5 Gy, the conventional biological indicator of dose, the dicentric assay, does not provide an accurate enough dose measurement. A more appropriate technique is to measure ring chromosomes in stimulated lymphocytes. Dose-effect relationships were obtained by plotting the frequencies of Premature Chromosome Condensation (PCC)-rings in PCC lymphocytes obtained by chemical induction with Calyculin A in vitro, irradiated with doses between 5 to 25 Gy. Cells were exposed either to neutron or to gamma rays and the corresponding dose effect curves are presented in this paper for the first time in literature. For the elaboration of these curves, 9 675 PCC cells in G1 G2 and M/A stages were analysed. The results were fitted to a lineal model in gamma irradiation up to 25 Gy. For neutron irradiation the data was fitted to a lineal model up to 10 Gy, and then dose saturation was observed. In conclusion, with this technique it is possible to set up dose effect curves up to 25 or 10 Gy according to the gamma or neutron radiation.
The estimation of the dose and the irradiated fraction of the body is important information in the primary medical response in case of a radiological accident. The PCC-R assay has been developed for high-dose estimations, but little attention has been given to its applicability for partial-body irradiations. In the present work we estimated the doses and the percentage of the irradiated fraction in simulated partial-body radiation exposures at high doses using the PCC-R assay. Peripheral whole blood of three healthy donors was exposed to doses from 0–20 Gy, with 60Co gamma radiation. To simulate partial body irradiations, irradiated and non-irradiated blood was mixed to obtain proportions of irradiated blood from 10–90%. Lymphocyte cultures were treated with Colcemid and Calyculin-A before harvest. Conventional and triage scores were performed for each dose, proportion of irradiated blood and donor. The Papworth's u test was used to evaluate the PCC-R distribution per cell. A dose-response relationship was fitted according to the maximum likelihood method using the frequencies of PCC-R obtained from 100% irradiated blood. The dose to the partially irradiated blood was estimated using the Contaminated Poisson method. A new D0 value of 10.9 Gy was calculated and used to estimate the initial fraction of irradiated cells. The results presented here indicate that by PCC-R it is possible to distinguish between simulated partial- and whole-body irradiations by the u-test, and to accurately estimate the dose from 10–20 Gy, and the initial fraction of irradiated cells in the interval from 10–90%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.