Although eye drops are frequently used as an initial treatment option for open angle glaucoma (OAG), side effects, and poor adherence, among others, may compromise treatment efficacy. In this scenario, laser trabeculoplasty is an interesting therapeutic option for open angle glaucoma cases. Commonly used for many years as a last alternative prior to glaucoma incisional surgery, laser trabeculoplasty has been changing its indication after the advent of selective laser trabeculoplasty (SLT ). In the current review, we critically evaluated the published data regarding the use of laser trabeculoplasty as a first treatment option for open angle glaucoma patients. Studies using SLT as a first-line treatment have encouraging findings. One-year efficacy results are comparable to those obtained with prostaglandin analogues, with a good safety profile. Although the laser´s effect is known to be transitory, recent data suggest it can be successfully repeated in cases with good response to the first SLT treatment.
Purpose: To compare the effects of the water-drinking test (WDT) with the 30° inverted body position test on intraocular pressure (IOP) in normal patients, suspected glaucoma patients and glaucoma patients.Materials and methods: Based on clinical evaluation of the optic disk, IOP, and standard achromatic perimetry (SAP) of 71 eyes, 18 were “normal” (normal SAP and optic disk evaluation, and IOP < 21 mm Hg), 30 were “glaucoma suspect” (GS; normal SAP, cup/disk (C/D) ratio > 0.5 or asymmetry > 0.2 and/or ocular hypertension), and 31 had “early glaucoma” (MD < -6 dB, glaucomatous optic neuropathy). Standard achromatic perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. Patients fasted before the WDT, and four measurements were performed at basal, 15’, 30, and 45’ after drinking 1 liter of water (WDT) in 5 minutes. In the 30° inverted position, IOP measurement with Perkins applanation tonometer was taken after 5 minutes lying down.Results: There was a statistical difference in all groups between the basal IOP and peak IOP during the WDT (p < 0.001) and in the inverted position IOP (p < 0.001). Controls (p = 0.50), suspects (p = 0.41) and glaucoma patients (p = 1.0) did not exhibit a difference between WDT-IOP and inverted position IOP.Conclusion: The 30° inverted position test was as efficient as WDT in detecting peak IOP. This new provocative test is easier, faster and more comfortable for both patients and doctors.How to cite this article: Kanadani FN, Moreira TCA, Campos LF, Vianello MP, Corradi J, Dorairaj SK, Freitas ALA, Ritch R. A New Provocative Test for Glaucoma. J Curr Glaucoma Pract 2016;10(1): 1-3.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.