Purpose Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative 177Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
Purpose Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guidelines for nuclear medicine departments setting up and developing their quantitative SPECT-CT service with guidance on protocols, harmonisation and clinical use cases. Methods These practice guidelines were written by members of the European Association of Nuclear Medicine Physics, Dosimetry, Oncology and Bone committees representing the current major stakeholders in Quantitative SPECT-CT. The guidelines have also been reviewed and approved by all EANM committees and have been endorsed by the European Association of Nuclear Medicine. Conclusion The present practice guidelines will help practitioners, scientists and researchers perform high-quality quantitative SPECT-CT and will provide a framework for the continuing development of quantitative SPECT-CT as an established modality.
ObjectiveIodine-131-labelled meta-iodobenzylguanidine (131I-mIBG) therapy is an established treatment modality for relapsed/refractory neuroblastoma, most frequently administered according to fixed or weight-based criteria. We evaluate response and toxicity following a dosimetry-based, individualized approach.Materials and methodsA review of 44 treatments in 25 patients treated with 131I-mIBG therapy was performed. Patients received 131I-mIBG therapy following relapse (n=9), in refractory disease (n=12), or with surgically unresectable disease despite conventional treatment (n=4). Treatment schedule (including mIBG dose and number of administrations) was individualized according to the clinical status of the patient and dosimetry data from either a tracer study or previous administrations. Three-dimensional tumour dosimetry was also performed for eight patients.ResultsThe mean administered activity was 11089±7222 MBq and the mean whole-body dose for a single administration was 1.79±0.57 Gy. Tumour-absorbed doses varied considerably (3.70±3.37 mGy/MBq). CTCAE grade 3/4 neutropenia was documented following 82% treatments and grade 3/4 thrombocytopenia following 71% treatments. Further acute toxicity was found in 49% of patients. All acute toxicities resolved with appropriate therapy. The overall response rate was 58% (complete or partial response), with a further 29% of patients having stable disease.ConclusionA highly personalized approach combining patient-specific dosimetry and clinical judgement enables delivery of high activities that can be tolerated by patients, particularly with stem cell support. We report excellent response rates and acceptable toxicity following individualized 131I-mIBG therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.