The human hand is important for the performance of activities of daily living which are directly related to quality of life. Various conditions, such as Duchenne muscular dystrophy (DMD) can affect the function of the human hand and wrist. The ability to assess the impairment in the hand and the wrist by measuring the range of motion (ROM), is essential for the development of effective rehabilitation protocols. Currently the clinical standard is the goniometer. In this study we explore the feasibility and reliability of an optical sensor (Leap motion sensor) in measuring active hand/wrist ROM. We measured the hand/wrist ROM of 20 healthy adults with the goniometer and the Leap motion sensor, in order to check the agreement between the two methods and additionally, we performed a test-retest of the Leap motion sensor with 12 of them, to assess its reliability. The results suggest low agreement between the goniometer and the leap motion sensor, yet showing a large decrease in measurement time and high reliability when using the later. Despite the low agreement between the two methods, we believe that the Leap motion sensor shows potential to contribute to the development of hand rehabilitation protocols and be used with patients in a clinical setting.
ObjectiveWe aimed to compare patient’s and physician’s ratings of inhaled medication adherence and to identify predictors of patient-physician discordance.DesignBaseline data from two prospective multicentre observational studies.Setting29 allergy, pulmonology and paediatric secondary care outpatient clinics in Portugal.Participants395 patients (≥13 years old) with persistent asthma.MeasuresData on demographics, patient-physician relationship, upper airway control, asthma control, asthma treatment, forced expiratory volume in one second (FEV1) and healthcare use were collected. Patients and physicians independently assessed adherence to inhaled controller medication during the previous week using a 100 mm Visual Analogue Scale (VAS). Discordance was defined as classification in distinct VAS categories (low 0–50; medium 51–80; high 81–100) or as an absolute difference in VAS scores ≥10 mm. Correlation between patients’ and physicians’ VAS scores/categories was explored. A multinomial logistic regression identified the predictors of physician overestimation and underestimation.ResultsHigh inhaler adherence was reported both by patients (median (percentile 25 to percentile 75) 85 (65–95) mm; 53% VAS>80) and by physicians (84 (68–95) mm; 53% VAS>80). Correlation between patient and physician VAS scores was moderate (rs=0.580; p<0.001). Discordance occurred in 56% of cases: in 28% physicians overestimated adherence and in 27% underestimated. Low adherence as assessed by the physician (OR=27.35 (9.85 to 75.95)), FEV1 ≥80% (OR=2.59 (1.08 to 6.20)) and a first appointment (OR=5.63 (1.24 to 25.56)) were predictors of underestimation. An uncontrolled asthma (OR=2.33 (1.25 to 4.34)), uncontrolled upper airway disease (OR=2.86 (1.35 to 6.04)) and prescription of short-acting beta-agonists alone (OR=3.05 (1.15 to 8.08)) were associated with overestimation. Medium adherence as assessed by the physician was significantly associated with higher risk of discordance, both for overestimation and underestimation of adherence (OR=14.50 (6.04 to 34.81); OR=2.21 (1.07 to 4.58)), while having a written action plan decreased the likelihood of discordance (OR=0.25 (0.12 to 0.52); OR=0.41 (0.22 to 0.78)) (R2=44%).ConclusionAlthough both patients and physicians report high inhaler adherence, discordance occurred in half of cases. Implementation of objective adherence measures and effective communication are needed to improve patient-physician agreement.
Omalizumab was a safe and effective corticosteroid alternative for maintaining long-term remission of symptoms in these patients. Treatment intervals required individual patient-by-patient determination. The drug did not seem to alter the natural history of the disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.