The presented study is focused on the impact of binding zone location on immunochromatographic test strips on the analytical parameters of multiplex lateral flow assays. Due to non-equilibrium conditions for such assays the duration of immune reactions influences significantly the analytical parameters, and the integration of several analytes into one multiplex strip may cause an essential decrease of sensitivity. To choose the best location for binding zones, we have tested reactants for immunochromatographic assays of lincomycin, chloramphenicol, and tetracycline. The influence of the distance to the binding zones on the intensity of coloration and limit of detection (LOD) was rather different. Basing on the data obtained, the best order of binding zones was chosen. In comparison with non-optimal location the LODs were 5–10 fold improved. The final assay provides LODs 0.4, 0.4 and 1.0 ng/mL for lincomycin, chloramphenicol, and tetracycline, respectively. The proposed approach can be applied for multiplexed assays of other analytes.
Determining antibiotic concentration in human blood provides useful pharmacokinetic information. Commonly used methods such as ELISA require a long time to obtain results and thus cannot be applied when information is needed immediately. In this study, a novel antibody-based lateral flow technique was developed for tetracycline detection in human serum. Contrary to tests developed to analyze food samples, the features of work with serum as analyzed probe were studied for the first time here. The application of labeled and unlabeled specific antibodies was compared. For this purpose, specific and anti-species antibodies were labeled with gold nanoparticles and used for antigen–antibody interaction on the membrane surface with observed staining in the test zone. For both schemes, optimal conditions were established to provide the best sensitivity. The developed assay has a limit of visual detection as low as 35 and 11 ng/mL for the direct and indirect labeled antibodies, respectively. The limit of instrumental detection is from 0.4 to 3.5 ng/mL for diluted and undiluted sera. The use of indirect antibody labeling showed a small increase in sensitivity compared to traditional direct antibody labeling. The developed method showed no cross-reactivity with antibiotics of other classes. The method was used to test samples of serum. The results showed high correlation with the data obtained by ELISA (R2 = 0.98968). The assay provides a quick assessment of the amount of antibiotics in the blood and keeps them under control throughout the duration of therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.