The paper proposes a simple and less expensive gas chromatographic method for analyzing acrylamide in food and reveals comparative results regarding the acrylamide content in commercial and home toasted bread. Validation of the method has been achieved by establishing parameters linearity, limit of detection (LOD = 0.1 mg/L), limit of quantization (LOQ = 0.5 mg/L), precision, stability. Run-to-run precision was determined by carrying out five replicate determinations for three acrylamide standard solutions: 0.5 mg/L (RSD = 2.95 %), 1.0 mg/L (RSD = 1.05 %), and 5.0 mg/L (RSD = 0.84 %). The day-today precision was calculated by performing five replicate determinations in three different days: 0.5 mg/L (RSD = 2.54 %), 1.0 mg/L (RSD = 1.31 %), 5.0 mg/L (RSD = 1.16 %). The applicability of the method was demonstrated by analyzing different types of commercial and home toasted bread and by establishing the dependence of acrylamide levels on toasting time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.