The group contribution method UNIFAC has become very popular because of its availability via commercial process simulators, its reliably predicted vapor-liquid equilibrium (VLE) results, its simple usage, and, above all, its large range of applicability. Nevertheless, the original UNIFAC shows a few weaknesses. For example, there is no chance to describe simultaneously VLE data and excess enthalpies with the required accuracy. This means that the temperature dependence of the activity coefficient following the Gibbs-Helmholtz equation cannot be described correctly. Furthermore, predictions of the real phase behavior in the dilute region and for asymmetric systems can lead to poor results. The aim of this paper is to show how the mentioned weaknesses were overcome by using modified UNIFAC (Dortmund) instead of the original UNIFAC method, in which the required temperature-dependent parameters are fitted simultaneously to a large database covering various types of reliable phase equilibrium and excess property data. Furthermore, 10 new modified UNIFAC (Dortmund) parameter pairs for the new main group "epoxides" and the interactions between aromatics and perfluorinated compounds are given.
Solid-liquid equilibria of the following 11 alcohol systems have been measured by the visual method: cyclohexanol + dodecane, cyclohexanol + cyclohexane, cyclohexanol + benzene, cyclohexanol + tetrachloromethane, 1-butanol + water, 2-butanol + water, 2-methyl-1-propanol + water, 2-pentanol + tetrachloromethane, 1-pentanol + cyclohexane, 2-pentanol + cyclohexane, and 3-pentanol + cyclohexane. For all systems, with the exception of the system cyclohexanol + cyclohexane, eutectic behavior is assumed. With the visual technique not all systems can be determined over the whole concentration range because the mixtures become very viscous at low temperatures and high alcohol concentrations. Therefore the systems cyclohexanol + benzene, 2-butanol + water, and 2-pentanol + cyclohexane were also studied by an analytical method, which is introduced in this paper. The experimental data of the eutectic systems were compared with predicted values using the modified UNIFAC (Dortmund) group contribution method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.