We have developed a 40-MHz, 64-element phased-array transducer packaged in a 2.5 x 3.1 mm endoscopic form factor. The array is a forward-looking semi-kerfed design based on a 0.68Pb(Mg(1/3)Nb(2/3))O(3) - 0.32PbTiO3 (PMN-32%PT) single-crystal wafer with an element-to-element pitch of 38 µm. To achieve a miniaturized form factor, a novel technique of wire bonding the array elements to a polyimide flexible circuit board oriented parallel to the forward looking ultrasound beam and perpendicular to the array was developed. A technique of partially dicing into the back of the array was also implemented to improve the directivity of the array elements. The array was fabricated with a single-layer P(VDF-TrFE)-copolymer matching layer and a polymethylpentene (TPX) lens for passive elevation focusing to a depth of 7 mm. The two-way -6-dB pulse bandwidth was measured to be 55% and the average electromechanical coupling (k(eff)) for the individual elements was measured to be 0.62. The one-way -6-dB directivities from several array elements were measured to be ±20°, which was shown to be an improvement over an identical kerfless array. The -3-dB elevation focus resulting from the TPX lens was measured to be 152 µm at the focal depth, and the focused lateral resolution was measured to be 80 µm at a steering angle of 0°. To generate beam profiles and images, the probe was connected to a commercial ultrasound imaging platform which was reprogrammed to allow for phased array transmit beamforming and receive data collection. The collected RF data were then processed offline using a numerical computing script to generate sector images. The radiation pattern for the beamformed transmit pulse was collected along with images of wire phantoms in water and tissue-equivalent medium with a dynamic range of 60 dB. Finally, ex vivo tissue images were generated of porcine brain tissue.
Background: External tagging of fish using pop-up satellite tags (PSATs) can cause trauma and stress associated with capture, handling, tagging injury and tag placement that impedes body function and mobility, and these can affect the behaviour of the fish. We measured short-term (days) post-release behavioural response of estuarine shortnose sturgeon to tagging with PSATs and high-frequency accelerometers.
Methods:We developed a secure, low-noise attachment method for high-resolution (50 Hz) accelerometer PSATs in shortnose sturgeon. The archived time series of acceleration was used to determine sturgeon post-tagging activity, estimate swimming speed, erratic behaviour and behavioural clusters in relation to ambient light level and temperature, depth and tidal flow.Results: Short-term (hours) post-release response was characterized by resting periods on the river bottom and decreased swimming activity that was associated with individual-specific modulations in the swimming gait and high-energy burst acceleration movements. Locomotion routines suggested a relation to tidal flow, yet the shortterm time series did not allow for routine movements to be classified.
Conclusions:The approach used provides a useful method of revealing behavioural modifications during the postrelease recovery period of PSAT-tagged fish. We discuss how short-term (acute) effects on behaviour and potential longer-term (chronic) effects on survival are especially relevant in tagging studies.
A digital receive beamformer implementing a "one sample per pixel" variable sampling technique is described. The sampling method reduces the required sampling rates by a factor of 3, and reduces the data capture rate by a factor of 2, in comparison with the previous systems based on variable sampling. The sampling method is capable of estimating broadband pulse envelopes accurate for bandwidths up to 83.0%. This beamforming method has been implemented on a field-programmable gate array with maximum transmit and receive delay errors measured to be less than ±1.0 ns. The beamformer was tested and verified on a previously described 45-MHz 64-element phased array. The system generates images with 128 lines, 512 pixels per RF line, and 2 transmit focal zones. The system generates images with approximately 55 dB of dynamic range and was tested by imaging wire targets submersed in a water bath, wire targets embedded in a tissue phantom, and real-time in vivo imaging of a human wrist.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.