Background-Sodium nitroprusside is one of several agents considered effective for treating the no-reflow phenomenon during acute coronary interventions. However, the coronary hyperemic dose responses and systemic hemodynamic effects of intracoronary nitroprusside have yet to be determined in humans. The purpose of this study was to compare the hyperemic and hemodynamic responses of intracoronary nitroprusside to intracoronary adenosine in patients during cardiac catheterization with angiographically normal anterior descending arteries. Methods and Results-In 21 patients, coronary blood flow velocity (0.014-inch Doppler flow wire), heart rate, and blood pressure were measured in unobstructed left anterior descending coronary arteries at rest, after intracoronary adenosine (30-to 50-g boluses), and after 3 serial doses (0.3-, 0.6-, and 0.9-g/kg boluses) of intracoronary nitroprusside. Coronary reserve was calculated as hyperemia/basal coronary flow velocity. In an additional 9 patients with intermediate stenoses (53Ϯ7%), 14 fractional flow reserve (FFR) measurements (using 0.014-inch pressure wire) were performed with both intracoronary adenosine and nitroprusside (0.6 g/kg). Intracoronary nitroprusside produced equivalent coronary hyperemia with a longer duration (Ϸ25%) compared with intracoronary adenosine. Intracoronary nitroprusside (0.9 g/kg) decreased systolic blood pressure by Ͻ20%, with minimal change in heart rate, whereas intracoronary adenosine had no effect on these parameters. FFR measurements with intracoronary nitroprusside were identical to those obtained with intracoronary adenosine (rϭ0.97). Conclusions-Compared with adenosine, intracoronary nitroprusside produces an equivalent but more prolonged coronary hyperemic response in normal coronary arteries. Intracoronary nitroprusside, in doses commonly used for the treatment of the no-reflow phenomenon, can produce sustained coronary hyperemia without detrimental systemic hemodynamics. On the basis of FFR measurements compared with adenosine, sodium nitroprusside also appears to be a suitable hyperemic stimulus for coronary physiological measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.