Adult outpatients attending the main sexually transmitted infection clinic of Bangui, Central African Republic, were prospectively subjected to a multiplex rapid diagnostic test for human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV). In group I (n = 208) of patients already followed for HIV, 6 (2.9%) were unexpectedly negative, thus corresponding to false positive for HIV by the national HIV algorithm; hepatitis B surface antigen and HCV positivities were high (18.7% and 4.3%, respectively). In group II (n = 71) of patients with unknown HIV status, at least 1 chronic viral disease was diagnosed in 26 (36.6%) patients, including 5 (7.1%) HIV, 17 (23.9%) HBV, and 3 (4.2%) HCV infections.
BackgroundThe new microcapillary and fluorescence-based EC IVD-qualified Muse™ Auto CD4/CD4% single-platform assay (EMD Millipore Corporation, Merck Life Sciences, KGaA, Darmstadt, Germany) for CD4 T cell numeration in absolute number and in percentage was evaluated using Central African patients’ samples compared against the reference EC IVD-qualified BD FACSCount (Becton–Dickinson, USA) flow cytometer.MethodsEDTA-blood samples from 124 adults, 10 adolescents, 13 children and 3 infants were tested in parallel at 2 reference laboratories in Bangui.ResultsThe Muse™ technique was highly reproducible, with low intra- and inter-run variabilities less than 15%. CD4 T cell counts of Muse™ and BD FACSCount in absolute number and percentage were highly correlated (r2 = 0.99 and 0.98, respectively). The mean absolute bias between Muse™ and BD FACSCount cells in absolute number and percentage were −5.91 cells/µl (95% CI −20.90 to 9.08) with limits of agreement from −77.50 to 202.40 cells/µl, and +1.69 %CD4 (95% CI ±1.29 to +2.09), respectively. The percentages of outliers outside the limits of agreement were nearly similar in absolute number (8%) and percentage (10%). CD4 T cell counting by Muse™ allowed identifying the majority of individuals with CD4 T cell <200, <350 or <750 cells/µl corresponding to the relevant thresholds of therapeutic care, with sensitivities of 95.5–100% and specificities of 83.9–100%.ConclusionsThe Muse™ Auto CD4/CD4% Assay analyzer is a reliable alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine immunological monitoring according to World Health Organization recommendations in HIV-infected adults as well as children living in resource-constrained settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.