<p>The measuring of flood events is associated with many challenges. Among them is the determination of flow velocities for the derivation of discharge. Most of the applied methods for velocity determination the disadvantage that they work in direct contact with water. This often makes measuring under critical flow conditions dangerous. Optical measurement methods have a great advantage because they can work remotely, i.e., without water contact.</p> <p>For representative discharge measurements, flow velocity measurements over the entire width of the river cross-section are required. This is a major challenge in the application of PTV, because visible particles must be present across the entire cross-section, which is not always the case. The potential measurement gaps in the surface velocity distribution have a negative effect on the quality of the discharge determination. Because optical measurement methods are relatively new in hydrology, there is not yet a standardised procedure with which the discharge can be determined.&#160;</p> <p>The "OptiQ" method presented here is an approach for determining discharge using PTV. This method is based on the continuity equation, which is dependent on two variables, the flow area and the mean flow velocity. The challenge here is to determine the depth-averaged flow velocity, because PTV is used to determine the surface velocity. To get the depth-averaged flow velocities, the PTV results are averaged over a transect and converted using a velocity coefficient. The arithmetic mean, the velocity area method (DIN EN ISO 748:2008-02) and the moving average are considered as averaging methods. A statistical approach was chosen for closing measurement gaps that occurred in the velocity distribution. In this approach, the measurement results with similar discharge conditions in the entire time series, i.e. PTV results for the same water levels, are statistically analysed, filtered and summarised in a lookup table. The gaps in the measurements due to missing particles are filled with the data from the lookup table.</p> <p>For the data collection, three camera gauges were installed at regular gauging stations of the Saxon State Agency for Environmental and Agricultural Monitoring (BfUL). The camera gauges recorded short video sequences at regular time intervals, which were used to determine the velocity distributions using the FlowVelo tool (Eltner et al., 2020). This resulted in three time series covering a period of 10-15 months. For the validation of the optical discharge time series, the regular water level and discharge measurements of the BfUL are used.&#160;</p> <p>The application of "OptiQ" shows a significant adjustment of the optically determined discharge data to the reference measurement at all three gauging stations. While acceptable results were determined with the arithmetic mean only at higher discharge, the results with the velocity area method and the moving average are similarly good at all discharges. At the gauging station in Elbersdorf, the average difference from the reference value could be reduced from 29% to 15% with "OptiQ". In the next step, it is planned to further develop the statistical model "OptiQ" by using Deep Learning.</p>
<p>The importance of optical measurement methods in hydrology is increasing in the last years. In contrast to conventional gauging techniques, they can be applied remotely, making the measurement safe for humans and equipment, even under difficult measurement conditions. One important hydrological parameter to measure is discharge. Deriving discharge with remote sensing can be done by applying particle tracking velocimetry (PTV) in combination with the velocity area method (VAM). VAM is a standardized and established method in hydrology. For reliable discharge results with the VAM, surface flow velocity measurements and thus trackable particles in the case of PTV usage are required across the entire width of the river cross section, which is not always the case in natural observation conditions. To fill these data gaps several statistical methods were investigated that incorporate information provided at different measurement times but with similar discharge conditions.</p><p>In this study, data were collected over longer time periods with different cameras at a gauging station of a medium scale river in Saxony, Germany. Stationary cameras recorded short videos, which are used to estimate the velocity distribution at the water surface using PTV incorporated in the FlowVelo tool (Eltner, 2020), and afterwards, to estimate the discharge using VAM. The obtained discharge time series from different cameras and camera positions were used to analyse the performance of different gap filling approaches. The results were compared to discharge and water level measurements of the official gauging station maintained by the federal measuring agency. They show, that the adjustment to the data of the reference measurements increases significantly by application of the gap filling methods. Next steps are to enhance the presented methods by using targeted data filtering and deep learning.</p><p><strong>Keywords</strong>: <em>velocity area method, particle tracking velocimetry, camera based discharge estimation</em></p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.