Despite of the agronomic importance for water management, few studies of sugarcane roots have been performed under field conditions during the crop cycle. The aim of this study was to determine the cumulative root density (L A ), root distribution on soil profile and the effective rooting depth (ERD) for three sugarcane cultivars using the minirhizotron method. A field experiment was done with sugarcane cultivars IACSP94-2094, IACSP94-2101 and SP79-1011 grown under subsurface drip fertigation. Soil chemical and physical characteristics were also evaluated. Root evaluations were taken at 38, 58, 123, 185 and 205 days during the second ratoon, considering the soil profile until 0.8 m depth. The highest L A and root growth rates were found up to 0.4 m soil layer for all cultivars. Root growth rate varied during the crop cycle, with the highest values being found between 38 and 58 days after ratoon (DAR). There was a genotypic variation in root growth, with IACSP94-2101 showing the highest L A of 12.9 mm cm
USO DE IMAGENS MULTIESPECTRAIS E TERMOGRÁFICAS PARA MONITORAMENTO DAS CONDIÇÕES HÍDRICAS DA CANA-DE-AÇÚCAR JANE MARIA DE CARVALHO SILVEIRA1; BERNARDO MOREIRA CÂNDIDO2; ANDRÉ LUIZ BARROS DE OLIVEIRA SILVA3; GLÁUCIA CRISTINA PAVÃO4; MAURO ALEXANDRE XAVIER5 E REGINA CÉLIA DE MATOS PIRES6 1 Pesquisador Doutor, Centro de Ecofisiologia e Biofísica, IAC, Avenida Doutor Theodureto de Almeida Camargo, 1.500, Caixa Postal 28, CEP 13012-970, Campinas, SP, Brasil, jane.silveira@sp.gov.br 2 Pesquisador Doutor, Centro de Solos e Recursos Ambientais, IAC, Avenida Barão de Itapura, 1.481, Botafogo, CEP 13020-902, Campinas, SP, Brasil, b.candido@iac.sp.gov.br 3 Doutor, Centro de Ecofisiologia e Biofísica, IAC, Avenida Doutor Theodureto de Almeida Camargo, 1.500, Caixa Postal 28, CEP 13012-970, Campinas, SP, Brasil, andreluiz.biologia@gmail.com 4 Doutoranda, Centro de Ecofisiologia e Biofísica, IAC, Avenida Doutor Theodureto de Almeida Camargo, 1.500, Caixa Postal 28, CEP 13012-970, Campinas, SP, Brasil, glauciapavao@gmail.com 5 Pesquisador Doutor, Centro de Cana, IAC, Rodovia Antônio Duarte Nogueira, km 321 (Anel Viário Contorno Sul) Caixa Postal 206 - CEP 14.001-97, Ribeirão Preto, SP, Brasil, mxavier@iac.sp.gov.br 6 Pesquisador Doutor, Centro de Ecofisiologia e Biofísica, IAC, Avenida Doutor Theodureto de Almeida Camargo, 1.500, Caixa Postal 28, CEP 13012-970, Campinas, SP, Brasil, regina.pires@sp.gov.br 1 RESUMO Dentre as principais cadeias produtivas do estado de São Paulo destaca-se a cana-de-açúcar, com cultivo de áreas extensas e importância econômica para produção de açúcar, etanol e bioenergia. Uma das técnicas que permeia os cultivos de cana-de-açúcar em grandes áreas e pode contribuir para maiores produtividades e qualidade da produção é a irrigação. Logo, torna-se fundamental conhecer os diferentes manejos de irrigação que podem ser aplicados em áreas extensas visando o uso eficiente da água e considerando o estado hídrico e o desenvolvimento das plantas. Neste sentido, o sensoriamento remoto trouxe benefícios para o cultivo da cana-de-açúcar com estudos de estimativa de biomassa, crescimento e vigor de plantas, mas poucos estudos mostraram resultados sobre monitoramento do estado hídrico da planta visando possibilidades de manejo da irrigação considerando o déficit hídrico das plantas. O objetivo deste estudo foi avaliar alternativas para monitoramento do estado hídrico da cana-de-açúcar com uso de câmeras termográficas e multiespectral acopladas em veículo aéreo não tripulável (VANT). As avaliações permitiram registrar diferenças entre os tratamentos irrigados quando comparados aos tratamentos sem irrigação nas duas câmeras utilizadas. As imagens termográficas tem potencial para avaliação do estado hídrico de plantas de cana-de-açúcar de modo rápido, não destrutivo e eficiente. Palavras-chave: sensoriamento remoto, irrigação, estresse hídrico, RPA SILVEIRA, J. M. C.; CÂNDIDO, B. M.; SILVA, A. L. B. O.; PAVÃO; G. C.; XAVIER, M. A. E PIRES, R. C. M. MULTISPECTRAL AND THERMOGRAPHIC IMAGES FOR MONITORING THE WATER CONDITIONS OF SUGARCANE 2 ABSTRACT Among the main production chains in the state of São Paulo, sugarcane stands out, with the cultivation of extensive areas and economic importance for sugar, ethanol and bioenergy production. One of the techniques that permeate sugarcane crops in large areas and can contribute to higher productivity and production quality is irrigation. Therefore, it is essential to know the different irrigation management that can be applied in extensive areas aimed at the efficient use of water and considering the water status and plant development. In this sense, remote sensing brought benefits for sugarcane cultivation with studies of biomass estimation, plant growth and vigor, but few studies have shown results on monitoring the water status of the plant aiming at irrigation management possibilities considering the water deficit of plants. In this context, this study evaluated alternatives for monitoring the water status of sugarcane with the use of thermographic and multispectral cameras embedded in an unmanned aerial vehicle. The evaluations allowed recording differences between irrigated treatments compared to treatments without irrigation in the two cameras used. Thermographic images can evaluate the water status of sugarcane plants quickly, nondestructively and efficiently. Keywords: remote sensing, irrigation, water stress, UAV
CALIBRATION AND ACCURACY OF TWO ELECTROMAGNETIC METHODS OF SOIL MOISTURE MEASUREMENT IN OXISOL ANDRÉ LUIZ BARROS DE OLIVEIRA SILVA1; REGINA CÉLIA DE MATOS PIRES2; AUGUSTO YUKITAKA PESSINATTI OHASHI3; GLAUCIA CRISTINA PAVÃO4 E GABRIEL CONSTANTINO BLAIN5 1PhD student, Postgraduate in Tropical and Subtropical Agriculture, Agronomic Insitute, 1481 Barao de Itapura Ave, Campinas, P.O. Box: 28, Sao Paulo, Brazil. andreluiz.biologia@gmail.com. 2 Scientific researcher, Agronomic Insitute, 1481 Barao de Itapura Ave, Campinas, P.O. Box: 28, Sao Paulo, Brazil. rcmpires@iac.sp.gov.br. 3PhD student, Postgraduate in Tropical and Subtropical Agriculture, Agronomic Insitute, 1481 Barao de Itapura Ave, Campinas, P.O. Box: 28, Sao Paulo, Brazil. augusto.ohashi@gmail.com. 4PhD student, Postgraduate in Tropical and Subtropical Agriculture, Agronomic Insitute, 1481 Barao de Itapura Ave, Campinas, P.O. Box: 28, Sao Paulo, Brazil. glauciapavao@gmail.com. 5Scientific researcher, Agronomic Insitute, 1481 Barao de Itapura Ave, Campinas, P.O. Box: 28, Sao Paulo, Brazil. gabriel@iac.sp.gov.br. 1 ABSTRACT Accurately measuring soil moisture is an important technological challenge. Sensors development and validation for agricultural applications is a relevant research theme. Electromagnetic techniques have been shown to be useful for soil moisture measurement. However, these techniques typically benefit from calibration. In this context, the aim of this study was to calibrate and evaluate the accuracy and precision of the soil moisture measured by two devices with different electromagnetic principles: Frequency Domain Reflectometry (FDR) e High Frequency Soil Impedance (HFSI) in the laboratory with in oxisol. The probes used were Diviner 2000 and Hidrofarm HFM 1010. Soil moisture was measured using both FDR and HFSI probes. A large variation in soil moisture values occurred during the experiment, as it varied from 0.489 m3 m-3 to 0.077 m3 m-3. Both electromagnetic methods showed good correlation compared to the standard method (gravimetric). HFSI probe overestimated the soil moisture values when compared to the gravimetric method, while FDR underestimated the values. Keywords: capacitance probes, HFSI sensor, FDR sensor, high frequency soil impedance. SILVA, A. L. B. O.; PIRES, R. C. M.; OHASHI, A. Y. P.; PAVÃO, G. C.; BLAIN, G. C. CALIBRAÇÃO E PRECISÃO DE DOIS MÉTODOS ELETROMAGNÉTICOS DE MEDIÇÃO DE UMIDADE DO SOLO EM OXISOL 2 RESUMO Medir a umidade do solo com precisão é um importante desafio. O desenvolvimento e validação de sensores para aplicações agrícolas é um tema de pesquisa relevante. As técnicas eletromagnéticas demonstraram ser úteis para a medição da umidade do solo. No entanto, essas técnicas geralmente se beneficiam da calibração. Nesse contexto, o objetivo deste estudo foi calibrar e avaliar a exatidão e precisão da umidade do solo, medida por dois dispositivos com diferentes princípios eletromagnéticos: Reflectometria no Domínio da Frequência (FDR) e Impedância do Solo de Alta Frequência (HFSI) em laboratório em latossolo. As sondas utilizadas foram Diviner 2000 e Hydrofarm HFM 1010. A umidade do solo foi medida usando as sondas FDR e HFSI. Houve uma grande variação nos valores de umidade do solo durante o experimento, de 0,489 m3 m-3 a 0,077 m3 m-3. Ambos os métodos eletromagnéticos mostraram boa correlação em comparação com o método padrão (gravimétrico). A sonda HFSI superestimou os valores de umidade do solo quando comparada ao método gravimétrico, enquanto a FDR subestimou os valores. Palavras-chave: sondas de capacitância, sensor HFSI, sensor FDR, impedância do solo em alta frequência.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.