Ambient seismic noise measurements were conducted inside the Holweide Hospital (Cologne) for checking whether its frequencies of vibration fall into the range where soil amplification is expected. If this is the case, damage might increase in case of an earthquake due to an amplified structural response of the building. Two different techniques were used: the ratio between the horizontal and vertical components of the spectra recorded at stations located inside the building and the ratio between the corresponding components of the spectra recorded simultaneously inside the building and at a reference station placed outside. While the former method might be preferred because of less equipment involved, the latter has the advantage of producing more stable results and deleting automatically the influence of the sedimentary cover, which might obscure some eigenfrequencies of vibration of the building. An independently performed finite-element analysis of the hospital showed a good correlation between measured and calculated eigenmodes.
An overlap in frequency between the 1D resonance frequency of sediments and the vibrational frequencies of long-span bridges might lead to a strongly increased structural response of the latter. Interference of surface waves caused by reflections at dipping interfaces may introduce additional unfavourable amplifications. Therefore, the vulnerability of two bridges crossing the Rhine River in Cologne, Germany, was assessed using ground motion scenarios computed for four profiles crossing the Lower Rhine Embayment. Due to their vibrational frequencies being in the vicinity of resonant peaks in the response spectra, the Severinsbridge showed critical loading and the bridge Cologne-Deutz even exhibited grave failure according to the dynamic FE-simulations.
Ambient seismic noise measurements were conducted inside the Cathedral of Cologne (Germany) for assessing its frequencies of vibration and for checking whether these occur in the range where soil amplification is expected. If this is the case, damages may increase in case of an earthquake due to an increased structural response of the building. Analysis of the ratio between the horizontal and vertical components of the spectra recorded at stations located inside the building as well as the ratio between the corresponding components of the spectra recorded simultaneously inside the building and at a reference station placed in the basement of the cathedral indicated several modes of vibration. Facilitated by these results an assessment of the seismic vulnerability was attempted for a 2D ground motion scenario using the finite element method.
Moderne Bauwerke müssen heute eine hohe energetische Leistungsfähigkeit aufweisen und gleichzeitig alle einwirkenden Lasten sicher abtragen. Dies stellt insbesondere in Erdbebengebieten hohe Anforderungen an die verwendeten Baustoffe. Am baupraktischen Beispiel einer Doppelhaushälfte wird demonstriert, dass die Symbiose aus energieeffizientem und gleichzeitig erdbebensicherem Bauen in der höchsten deutschen Erdbebenzone mit monolithischem Ziegelmauerwerk gut realisierbar ist. Als Ziegelmauerwerk werden für die Außenwände wärmetechnisch optimierte Hochlochziegel verwendet, die sowohl die Anforderungen der Energieeinsparverordnung 2009 als auch die Anforderungen an Mauerwerkbaustoffe nach den aktuellen Erdbebennormen erfüllen. Der Erdbebennachweis der Doppelhaushälfte erfolgt mit einem nichtlinearen Nachweisverfahren, das für eine einfache praktische Anwendung programmtechnisch umgesetzt wurde. Für den Nachweis wurden aus zyklischen Schubwandversuchen ermittelte Last-Verformungskurven verwendet. Das gesamte in Deutschland noch nicht normativ geregelte Nachweiskonzept wurde im Rahmen einer Zustimmung im Einzelfall geprüft und genehmigt.Energy-efficient and earthquake-proof building with monolithic brickwork. Nowadays, modern buildings need to have a high energetic performance and they have to withstand seismic actions at the same time. These contradictory demands can only be fulfilled by construction materials of high quality and optimal performance. On the example of a semi-detached building in Germany's highest earthquake-zone it is demonstrated that buildings made of monolithic brickwork meet all the requirements of energy efficiency and earthquake resistant design. The monolithic brickwork was carried out with thermo technical optimized vertical perforated bricks for the external walls. The used brick type fulfils all demands according to DIN 4149 and EnEV 2009. The structural safety of the semi-detached building is verified by means of nonlinear deformation based method, which has been implemented into a user friendly software package. The pushover curves of the single shear walls are determined by cyclic shear wall tests. The procedure is not part of the German earthquake code yet and has been approved by national building authorities. ObjektbeschreibungDie zweigeschossigen, vollständig unterkellerten Doppelhaushälften sind mit hochwärmedämmendem Ziegelmauerwerk für die Außenwände erstellt. Bild 1 zeigt die Ansicht der Objekte, mit deren Bau Anfang Dezember 2009 begonnen wurde.Die Ansichten in den Bildern 2 und 3 zeigen, dass bei moderner Bauweise der Anteil der Wandflächen im Vergleich zur Fensterfläche infolge der offenen Bauweise immer weiter abnimmt. Dies ist aus Sicht eines erdbebengerechten Entwurfs problematisch, da im Grundriss zunehmend weniger aussteifende Schubwandflächen zur Verfügung stehen. Dadurch ist ein konventioneller Nachweis der Erdbebensicherheit nicht mehr möglich. Der Grundriss der untersuchten Doppelhaushälfte ist in Bild 4 dargestellt. Die Innenwände und die Wohnhaustrennwand sind mit ...
In den 1950er Jahren war im Nachkriegsdeutschland vieles denkbar und möglich. Man wollte die im Krieg zerstörten Städte wieder aufbauen, besser und schöner als zuvor, und suchte nach neuen, ideologisch unbelasteten architektonischen Ausdrucksformen und Motiven. Gleichzeitig war es eine Zeit des Mangels. Anfang der 1950er Jahre waren viele Städte noch Trümmerfelder. Angesichts des unermesslichen Verlusts an Bausubstanz und der Größe der Aufgabe mussten Mittel und Material gezielt und effizient eingesetzt werden.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.