Aims: In a recent preclinical study, we noticed that injection of cells in the urethral sphincter by needle through a cystoscope under visual control frequently yielded in misplacement or loss of cells. We, therefore, investigated if a needle-free waterjet device delivers viable cells under defined settings, including injection volume and pressure, fluid velocity and transportation media, precisely through the urothelium and connective tissue close to the sphincter muscle without full penetration of the sphincter apparatus. Methods: Mesenchymal stromal cells (MSCs) were prepared for needle-free waterjet injections. Upon injections into liquids cell viability and yield were investigated by trypan blue dye exclusion. Upon injection into cadaveric urethral tissue samples, cells were isolated from the urethrae and expanded to prove that this novel method delivered viable cells into the tissue. MSC injections by William's needle served as controls. Results: Waterjet injections of MSCs into isotonic cell culture medium resulted in equal or better yields of viable cells when compared with needle injections.Upon injection in urethral tissue samples, the waterjet technology facilitated fast and precise injections of viable cells through urothelial, mucosal and submucosal layers to reach the sphincter muscle. By controlling the injection pressure, loss of cells due to insufficient thrust or unintended full penetration was avoided.Conclusions: Needle-free waterjet injections deliver cells in the urethra faster and more precisely when compared with needle injections without compromising their viability. This is the first proof-of-concept study providing evidence that a waterjet transports viable cells precisely into the targeted tissue. K E Y W O R D S cell injection, cell therapy, medical technology, stress urinary incontinence, waterjet ---This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.Abbreviations: E, effect = pump setting, reflects a given pressure in an open system; IPCM, improved pressure control mode; LSM, laser scanning microscope; MSC, mesenchymal stromal cells; SUI, stress urinary incontinence; UPaCS, upgraded pump and controller system (based on ERBEJET 2).
Objectives To investigate the therapy of stress urinary incontinence in a preclinical setting cells were injected into the urethrae of minipigs; however, cells injected by William’s needle were frequently misplaced or lost; thus, we investigated if needle‐free cell injections using a novel waterjet technology facilitates precise injections in the urethral sphincter complex. Materials and Methods Porcine adipose tissue‐derived stromal cells (pADSCs) were isolated from boars, expanded, labelled, and injected in the sphincter of female pigs by waterjet employing two different protocols. After incubation for 15 min or 3 days, the urethrae of the pigs were examined. Injected cells were visualised by imaging and fluorescence microscopy of tissue sections. DNA of injected male cells was verified by polymerase chain reaction (PCR) of the sex‐determining region (SRY) gene. Cell injections by William’s needle served as controls. Results The new waterjet technology delivered pADSCs faster and with better on‐site precision than the needle injections. Bleeding during or after waterjet injection or other adverse effects, such as swelling or urinary retention, were not observed. Morphologically intact pADSCs were detected in the urethrae of all pigs treated by waterjet. SRY‐PCR of chromosomal DNA and detection of recombinant green fluorescent protein verified the injection of viable cells. In contrast, three of four pigs injected by William’s needle displayed no or misplaced cells. Conclusion Transurethral injection of viable pADSCs by waterjet is a simple, fast, precise, and yet gentle new technology. This is the first proof‐of‐principle concept study providing evidence that a waterjet injects intact cells exactly in the tissue targeted in a preclinical in vivo situation. To further explore the clinical potential of the waterjet technology longer follow‐up, as well as incontinence models have to be studied.
The reprogramming of patient´s somatic cells into induced pluripotent stem cells (iPSCs) and the consecutive differentiation into cardiomyocytes enables new options for the treatment of infarcted myocardium. In this study, the applicability of a hydrojet-based method to deliver footprint-free iPSC-derived cardiomyocytes into the myocardium was analyzed. A new hydrojet system enabling a rapid and accurate change between high tissue penetration pressures and low cell injection pressures was developed. Iron oxide-coated microparticles were ex vivo injected into porcine hearts to establish the application parameters and the distribution was analyzed using magnetic resonance imaging. The influence of different hydrojet pressure settings on the viability of cardiomyocytes was analyzed. Subsequently, cardiomyocytes were delivered into the porcine myocardium and analyzed by an in vivo imaging system. The delivery of microparticles or cardiomyocytes into porcine myocardium resulted in a widespread three-dimensional distribution. In vitro, 7 days post-injection, only cardiomyocytes applied with a hydrojet pressure setting of E20 (79.57 ± 1.44%) showed a significantly reduced cell viability in comparison to the cells applied with 27G needle (98.35 ± 5.15%). Furthermore, significantly less undesired distribution of the cells via blood vessels was detected compared to 27G needle injection. This study demonstrated the applicability of the hydrojet-based method for the intramyocardial delivery of iPSC-derived cardiomyocytes. The efficient delivery of cardiomyocytes into infarcted myocardium could significantly improve the regeneration.
We noted recently that the injection of cells with a needle through a cystoscope in the urethral sphincter muscle of pigs failed to deposit them nearby or at the intended target position in about 50% of all animals investigated (n > 100). Increasing the chance for precise cell injection by shotgun approaches employing several circumferential injections into the sphincter muscle bears the risk of tissue injury. In this study, we developed and tested a novel needle-free technique to precisely inject cells in the urethral sphincter tissue, or other tissues, using a water-jet system. This system was designed to fit in the working channels of endoscopes and cystoscopes, allowing a wide range of minimally invasive applications. We analyze key features, including the physical parameters of the injector design, pressure ranges applicable for tissue penetration and cell injections and biochemical parameters, such as different compositions of injection media. Our results present settings that enable the high viability of cells post-injection. Lastly, the method is suitable to inject cells in the superficial tissue layer and in deeper layers, required when the submucosa or the sphincter muscle of the urethra is targeted.
The Front Cover: The cover image is based on the ORIGINAL BASIC SCIENCE ARTICLE A novel waterjet technology for transurethral cystoscopic injection of viable cells in the urethral sphincter complex by Luise Jäger et al., https://doi.org/10.1002/nau.24261. Cover Credit: Cover image © Dept. Urology, UKT at EKUT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.