Background
The ease of implantation of the rapid deployment (RD) and sutureless valves has contributed to the adoption of anterior right thoracotomy (ART) approach for aortic valve replacement (AVR).
Aim of the study
This study evaluates the safety and haemodynamic performance of minimally invasive AVR through ART using the RD valves.
Methods
This is a retrospective, single‐center review of a total of 50 consecutive patients who received RD‐AVR through ART.
Results
The median age of patients was 75 years (interquartile range [IQR]: 69‐80), and median Euroscore II was 5.1 (IQR: 2.4‐7.5). ART RD‐AVR was successfully performed in all cases with no conversion to sternotomy, paravalvular leaks or need for valve explantation. The mean size of the implanted valve was 23.2 ± 2.3 mm. In‐hospital mortality was 2%. The mean and maximum pressure gradients across the aortic prosthesis were 10 mm Hg (IQR: 9‐12) and 19 mm Hg (IQR: 16‐23).
Conclusions
Rapid deployment aortic valve replacement can be safely performed through anterior right thoracotomy wit excellent haemodynamic performance and low postoperative complications rate.
BackgroundThoracic outlet syndrome (TOS) is a pathological condition caused by a narrowing between the clavicle and first rib leading to a compression of the neurovascular bundle to the upper extremity. The incidence of TOS is probably nowadays underestimated because the diagnosis could be very challenging without a thorough clinical examination along with appropriate clinical testing. Beside traditional supra-, infraclavicular or transaxillary approaches, the robotic assisted first rib resection has been gaining importance in the last few years.MethodsWe conducted a retrospective cohort analysis of all patients who underwent robotic assisted first rib resection due to TOS at Lucerne Cantonal Hospital and then we performed a narrative review of the English literature using PubMed, Cochrane Database of Systematic Reviews and Scopus.ResultsBetween June 2020 and November 2021, eleven robotic assisted first rib resections were performed due to TOS at Lucerne Cantonal Hospital. Median length of stay was 2 days (Standard Deviation: +/– 0.67 days). Median surgery time was 180 min (Standard Deviation: +/– 36.5). No intra-operative complications were reported.ConclusionsRobotic assisted first rib resection could represent a safe and feasible option in expert hands for the treatment of thoracic outlet syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.