Objectives: The precision of localizing the mandibular canal prior to surgical intervention depends on the achievable resolution, whereas identification of the nerve depends on the image contrast. In our study, we developed new protocols based on gradient and spin echo sequences. The results from both sequences were quantitatively compared for their agreement to identify the most suitable approach. Methods: By limiting the field of view to one side of the mandible, three-dimensional acquisitions with T 1 weighted gradient and spin echo sequences were performed with 0.5 3 0.5 3 0.5 mm 3 resolution within 6.5 min covering the mandibular canal from the mandibular to the mental foramen. Aliasing artefacts were suppressed by different techniques. A manual segmentation of the mandibular canal from seven healthy volunteers was performed on this section by three different observers. The surface distance of the segmented volumes was computed between both sequences as well as between the different observers as a measure of equality. Results: The quantitative comparison of the segmentation resulted in an average surface distance of 0.26 ± 0.05 mm between both sequences and an interobserver difference of 0.26 ± 0.08 mm for gradient and 0.29 ± 0.07 mm for spin echo data. By repeated evaluation, a difference of 0.15 ± 0.02 mm for gradient and 0.18 ± 0.03 mm for spin echo data was observed, indicating a slightly higher variability for spin echo images. Conclusions: Both sequences can be used to achieve high-resolution images with good contrast and can be used for precise localization of the mandibular canal. Despite a slightly increased difference for the spin echo data, the advantage of an easy and robust setup remains. Dentomaxillofacial Radiology (2017Radiology ( ) 46, 20160268. doi: 10.1259 Cite this article as: Kreutner J, Hopfgartner A, Weber D, Boldt J, Rottner K, Richter E, et al. High isotropic resolution magnetic resonance imaging of the mandibular canal at 1.5 T: a comparison of gradient and spin echo sequences.
The herein described method can be regarded as proof of principle that MRI is a promising option for digital impressions when fixed partial dentures are required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.