Isoelectric buffers are attractive for electrophoresis because of their low conductivity, and their compatibility with indirect photometric detection in capillary electrophoresis (CE) where they do not interfere with the detection by exhibiting competitive displacement of the UV-absorbing probe ion. N-carboxymethylated polyethyleneimine (CMPEI) was prepared by introducing a half molar equivalent of carboxylate groups onto a polyethyleneimine backbone. Its isoelectric point determined by conductometric titration and from the pH of its dilute aqueous solution is approx. 6.8, which allows isoelectric buffering at a lower pH compared to histidine (pI7.7). Although the isoelectric point is somewhat diffuse, as expected for a polymeric compound, it exhibits a buffering capacity at a pI point of about twice that of histidine. Studies of electroosmotic flow (EOF) profile at various pH values in fused silica capillaries showed that CMPEI adsorbs onto the fused silica wall and reverses the EOF at pH < 6.5. CMPEI was applied as a buffer in an electrolyte containing 0.5 mM of the anionic dye tartrazine used as the probe for indirect detection of anions. The separation system exhibited a stable baseline, no system peaks, separation efficiencies of up to 195,000 theoretical plates, and detection limits down to 0.2 microM or 2 amol of injected analyte.
A method for the separation of the polythionates (SxO6(2-), x = 3-5) in gold thiosulfate leach solutions using ion-interaction chromatography with conductivity and ultraviolet (UV) detection is described. Polythionates were eluted within 18 min using an eluent comprising an acetonitrile step gradient at 0.0 min from 15% v/v to 28% v/v, 3 mM TBAOH, and 2.5 mM sodium carbonate, operated using a Dionex NS1-5 micron column with guard. The developed method was capable of separating the gold thiosulfate complex ion in standard solutions, but quantification of this species in realistic leach solutions proved impractical due to a self-elution effect that caused the gold peak to be eluted as a broad band. Detection limits for polythionates using a 10 microL injection volume ranged between 1-6 mg L(-1) (5-23 microM) for conductivity and 0.8-13 mg L(-1) (4-68 microM) for UV detection, based on a signal-to-noise ratio of 2. Calibration was linear over the ranges 5-2000, 10-2000 and 25-2500 mg L(-1) for trithionate, tetrathionate and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20 % m/v gold ore.
The partial reduction of pyrroles is not a common practice even though it offers a potential route to pyrroline building blocks, commonly used for synthesis. We have investigated the reduction of 2-acyl-N-sulfonylpyrroles and by varying the hydride source and solvent, achieved a chemoselective reduction, leading to 3-pyrrolines and alkyl pyrroles in high yield.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.