Background: Inflation of the gastrointestinal lumen is vital for proper visualization during endoscopy. Air, insufflated via the endoscope, is gradually being replaced with carbon dioxide (CO 2 ) in many centers, with the intention of minimizing post-procedural discomfort due to retained gas. Recent studies suggest that the use of CO 2 during pediatric esophagogastroduodenoscopy (EGD) with an unprotected airway is associated with transient elevations in exhaled CO 2 (end-tidal CO 2 , EtCO 2 ), raising safety concerns. One possible explanation for these events is eructation of insufflation gas from the stomach. Objectives: To distinguish eructated versus absorbed CO 2 by sampling EtCO 2 from a protected airway with either laryngeal mask airway (LMA) or endotracheal tube (ETT), and to observe for changes in minute ventilation (MV) to exclude hypoventilation events. Methods: Double-blinded, randomized clinical trial of CO 2 versus air insufflation for EGD with airway protection by either LMA or ETT. Tidal volume, respiratory rate, MV, and EtCO 2 were automatically recorded every minute. Cohort demographics were described with descriptive characteristics. Variables including the percent of children with peak, transient EtCO 2 ≥ 60 mmHg were compared between groups. Results: One hundred ninety-five patients were enrolled for 200 procedures. Transient elevations in EtCO 2 of ≥60 mmHg were more common in the CO 2 group, compared to the air group (16% vs 5%, P = 0.02), but were mostly observed with LMA and less with ETT. Post-procedure pain was not different between groups, but flatulence was reported more with air insufflation ( P = 0.004). Conclusion: Transient elevations in EtCO 2 occur more often with CO 2 than with air insufflation during pediatric EGD despite protecting the airway with an LMA or, to a lesser degree, with ETT. These elevations were not associated with changes in MV. Although no adverse clinical effects from CO 2 absorption were observed, these findings suggest that caution should be exercised when considering the use of CO 2 insufflation, especially since the observed benefits of using this gas were minimal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.