A dynamic two-phase imbalance mechanism model of pressurizer in pressurized water reactor (PWR) nuclear power plant was built based on some reasonable simplifications and basic assumptions. The equations of energy and mass conservation are used in obtaining a mathematical model for pressurizer operation. The pressurizer is divided into two regions, steam region and liquid region but not necessary in equilibrium with each other. Considering the influence of the spray flow, surge flow, safety valve and heater, the model of pressurizer pressure control system is established by MATLAB/Simulink in this paper. For the large overshoot, response delay and poor stability exist in the pressurizer pressure control system, an advanced model based on PID control algorithm is proposed. The simulation results were compared between two different data obtained by foreign PWR nuclear power plant simulator. All the compared data are quite similar in simulation result, hence it proves the simulation result quite accurate and yet the mathematical model obtained has proved its working principles successfully.
This paper presents a wireless fire alarm system in power plant. In the wireless fire alarm system had two sensors like smoke sensor and temperature sensor. The smoke sensor is detected the smoke when during the fire disaster happens. The fire disaster happens the temperature will increase to above 65 0 C all the wire will burnt and will getting smoke around the room. When the smoke sensor and the temperature sensor had signal will pass through to microcontroller PIC18F4550 and send the data to computer with using X-bee Pro device. The X-bee Pro will receive signal to computer and show in the Visual Basic about the status of the room and the temperature at the room.
A dynamic two-phase imbalance mechanism model of pressurizer in pressurized water reactor (PWR) nuclear power plant was built based on some reasonable simplifications and basic assumptions. The equations of energy and mass conservation are used in obtaining a mathematical model for pressurizer operation. The pressurizer is divided into two regions, steam region and liquid region but not necessary in equilibrium with each other. Considering the influence of the spray flow, surge flow, safety valve and heater, the model of pressurizer pressure control system is established by MATLAB/Simulink in this paper. For the large overshoot, response delay and poor stability exist in the pressurizer pressure control system, an advanced model based on PID control algorithm is proposed. The simulation results were compared between two different data obtained by foreign PWR nuclear power plant simulator. All the compared data are quite similar in simulation result, hence it proves the simulation result quite accurate and yet the mathematical model obtained has proved its working principles successfully.
This paper presents a wireless fire alarm system in power plant. In the wireless fire alarm system had two sensors like smoke sensor and temperature sensor. The smoke sensor is detected the smoke when during the fire disaster happens. The fire disaster happens the temperature will increase to above 65 0 C all the wire will burnt and will getting smoke around the room. When the smoke sensor and the temperature sensor had signal will pass through to microcontroller PIC18F4550 and send the data to computer with using X-bee Pro device. The X-bee Pro will receive signal to computer and show in the Visual Basic about the status of the room and the temperature at the room.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.