When using modern highly efficient internal combustion engines with lowered
potential of exhaust heat the heat recovery systems receive increasing
attention. The efficiency of combustion exhaust heat recovery at the low
potential level can be enhanced by deep cooling the combustion products
below a dew point temperature, which is practically the only possibility for
reducing the temperature of boiler exhaust gas, while ensuring the
reliability, environmental friendliness and economy of power plant. The aim
of research is to investigate the influence of multiplicity of circulation
and temperature difference at the exit of exhaust gas boiler heating
surfaces, which values are varying as 20, 15, 10?C, on exhaust gas boiler
characteristics. The calculations were performed to compare the constructive
and thermal characteristics of the various waste heat recovery circuits and
exhaust gas boiler of ship power plant. Their results showed that due to
application of condensing heating surfaces in exhaust gas boiler the total
heat capacity and steam capacity of exhaust gas boiler increases. The
increase of exhaust gas boiler heat capacity is proportional to the growth
of its overall dimensions. A direct-flow design of the boiler provides a
significant increase in heat efficiency and decrease in dimensions. In
addition, a direct-flow boiler circuit does not need steam separator,
circulation pump, the capital cost of which is about half (or even more) of
heating surface cost.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.