Robotic training paradigms that enforce a fixed kinematic control might be suboptimal for rehabilitative training because they abolish variability, an intrinsic property of neuromuscular control (Jezernik et al., 2003). In the present study we introduce "assist-as-needed" (AAN) robotic training paradigms for rehabilitation of spinal cord injury subjects. To test the efficacy of these robotic control strategies to teach spinal mice to step, we divided 27 adult female Swiss-Webster mice randomly into three groups. Each group was trained robotically by using one of three control strategies: a fixed training trajectory (Fixed group), an AAN training paradigm without interlimb coordination (Band group), and an AAN training paradigm with bilateral hindlimb coordination (Window group). Beginning at 14 d after a complete midthoracic spinal cord transection, the mice were trained daily (10 min/d, 5 d/week) to step on a treadmill 10 min after the administration of quipazine (0.5 mg/kg), a serotonin agonist, for a period of 6 weeks. During weekly performance evaluations, the mice trained with the AAN window paradigm generally showed the highest level of recovery as measured by the number, consistency, and periodicity of steps during the testing sessions. In all three measurements there were no significant differences between the Band and the Fixed training groups. These results indicate that the window training approach, which includes loose alternating interlimb coordination, is more effective than a fixed trajectory paradigm with rigid alternating interlimb coordination or an AAN paradigm without any interlimb constraints in promoting robust postinjury stepping behavior.
Novel flexible parylene-based high-density electrode arrays have been developed for functional electrical stimulation in retinal and spinal cord applications. These electrode arrays are microfabricated according to single-metal-layer and, most recently, dual-metal-layer processes. A new heat-molding process has been implemented to conform electrode arrays to approximate the curvature of canine retinas, and chronic implantation studies have been undertaken to study the mechanical effects of parylene-based prostheses on the retina, with excellent results to date. Electrode arrays have also been implanted and tested on the spinal cords of murine models, with the ultimate goal of facilitation of locomotion after spinal cord injury; these arrays provide a higher density and better spatial control of stimulation and recording than is typically possible using traditional fine-wire electrodes. Spinal cord stimulation typically elicited three muscle responses, an early (direct), a middle (monosynaptic), and a late (polysynaptic) response, classified based on latency after stimulation. Stimulation at different rostrocaudal levels of the cord yielded markedly different muscle responses, highlighting the need for such high-density arrays.
For a complete adult spinal rat to regain some weight-bearing stepping capability, it appears that a sequence of specific proprioceptive inputs that are similar, but not identical, from step to step must be generated over repetitive step cycles. Furthermore, these cycles must include the activation of specific neural circuits that are intrinsic to the lumbosacral spinal cord segments. For these sensorimotor pathways to be effective in generating stepping, the spinal circuitry must be modulated to an appropriate excitability level. This level of modulation is sustained from supraspinal input in intact, but not spinal, rats. In a series of experiments with complete spinal rats, we have shown that an appropriate level of excitability of the spinal circuitry can be achieved using widely different means. For example, this modulation level can be acquired pharmacologically, via epidural electrical stimulation over specific lumbosacral spinal cord segments, and/or by use-dependent mechanisms such as step or stand training. Evidence as to how each of these treatments can "tune" the spinal circuitry to a "physiological state" that enables it to respond appropriately to proprioceptive input will be presented. We have found that each of these interventions can enable the proprioceptive input to actually control extensive details that define the dynamics of stepping over a range of speeds, loads, and directions. A series of experiments will be described that illustrate sensory control of stepping and standing after a spinal cord injury and the necessity for the "physiological state" of the spinal circuitry to be modulated within a critical window of excitability for this control to be manifested. The present findings have important consequences not only for our understanding of how the motor pattern for stepping is formed, but also for the design of rehabilitation intervention to restore lumbosacral circuit function in humans following a spinal cord injury.
In the present study, concurrent treatment with robotic step training and a serotonin agonist, quipazine, generated significant recovery of locomotor function in complete spinal cord-transected mice (T7-T9) that otherwise could not step. The extent of recovery achieved when these treatments were combined exceeded that obtained when either treatment was applied independently. We quantitatively analyzed the stepping characteristics of spinal mice after alternatively administering no training, manual training, robotic training, quipazine treatment, or a combination of robotic training with quipazine treatment, to examine the mechanisms by which training and quipazine treatment promote functional recovery. Using fast Fourier transform and principal components analysis, significant improvements in the step rhythm, step shape consistency, and number of weight-bearing steps were observed in robotically trained compared with manually trained or nontrained mice. In contrast, manual training had no effect on stepping performance, yielding no improvement compared with nontrained mice. Daily bolus quipazine treatment acutely improved the step shape consistency and number of steps executed by both robotically trained and nontrained mice, but these improvements did not persist after quipazine was withdrawn. At the dosage used (0.5 mg/kg body weight), quipazine appeared to facilitate, rather than directly generate, stepping, by enabling the spinal cord neural circuitry to process specific patterns of sensory information associated with weight-bearing stepping. Via this mechanism, quipazine treatment enhanced kinematically appropriate robotic training. When administered intermittently during an extended period of robotic training, quipazine revealed training-induced stepping improvements that were masked in the absence of the pharmacological treatment.
The importance of the in vivo dynamic nature of the circuitries within the spinal cord that generate locomotion is becoming increasingly evident. We examined the characteristics of hindlimb EMG activity evoked in response to epidural stimulation at the S1 spinal cord segment in complete midthoracic spinal cord-transected rats at different stages of postlesion recovery. A progressive and phasedependent modulation of monosynaptic (middle) and long-latency (late) stimulation-evoked EMG responses was observed throughout the step cycle. During the first 3 weeks after injury, the amplitude of the middle response was potentiated during the EMG bursts, whereas after 4 weeks, both the middle and late responses were phase-dependently modulated. The middle-and late-response magnitudes were closely linked to the amplitude and duration of the EMG bursts during locomotion facilitated by epidural stimulation. The optimum stimulation frequency that maintained consistent activity of the long-latency responses ranged from 40 to 60 Hz, whereas the shortlatency responses were consistent from 5 to 130 Hz. These data demonstrate that both middle and late evoked potentials within a motor pool are strictly gated during in vivo bipedal stepping as a function of the general excitability of the motor pool and, thus, as a function of the phase of the step cycle. These data demonstrate that spinal cord epidural stimulation can facilitate locomotion in a time-dependent manner after lesion. The long-latency responses to epidural stimulation are correlated with the recovery of weight-bearing bipedal locomotion and may reflect activation of interneuronal central pattern-generating circuits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with đŸ’™ for researchers
Part of the Research Solutions Family.