tropical coastal area. During 6 months the composition of rain samples collected simultaneously over 24h with an open collector and with an automatic opened collector (KFA -J¸lich Type) at 500m of the Atlantic coastline of Salvador were compared. All average concentrations were higher for the "total" samples than for the "wet only" samples, except for hydrogen ions, nitrate and ammonium.Keywords: total deposition; wet only deposition; rain sampling. ARTIGO INTRODUÇÃOAmostras de precipitação podem ser coletadas usando-se coletores de deposição total ou de deposição apenas úmida. Sabe-se que para garantir a representatividade de um evento chuvoso são igualmente necessários cuidados quanto à coleta da precipitação, estocagem da amostra e análise dos seus constituintes. Existem na literatura inúmeros trabalhos publicados sobre estudos de caracterização da deposição úmida em diversas partes do mundo e muitos outros com diferentes objetivos. No entanto, a escolha da metodologia amostral, que é influenciada pelos objetivos do estudo, assim como por aspectos econômicos e logísticos é quase sempre apontada sem maiores justificativas e pouquíssimo se encontra sobre a comparação entre os dados obtidos com os dois tipos de amostragem. Adicionalmente, a maioria dos trabalhos publicados que se referem a dados desse tipo, devido a objetivos específicos do estudo, comparam concentrações, médias de componentes da precipitação amostrada das duas formas, mas não simultaneamente 1-3 , ou comparam as amostras analisadas por laboratórios diferentes e até mesmo usando metodologias analíticas diferentes para alguns componentes 4 . Por outro lado, esses dados encontrados na literatura são para áreas com diferentes características da área onde foi efetuado este estudo. Obviamente, espera-se a priori diferenciação na composição da chuva amostrada simultaneamente com os dois tipos de coletores, uma vez que a amostragem da deposição total (coletor aberto permanentemente, durante eventos chuvosos e períodos secos) refere-se à coleta dos componentes atmosfé-ricos da deposição úmida (chuva) e seca (gases dispersos e partículas em suspensão), enquanto que a amostragem da deposição apenas úmida (coletor aberto exclusivamente durante o evento chuvoso) inclui em termos de deposição seca somente a fração que é retirada da atmosfera durante a chuva. Além disso, os coletores de deposição total são susceptí-veis à evaporação de água e de componentes voláteis da amostra, particularmente sob condições de temperaturas elevadas ou longos períodos de exposição. Estes coletores têm sido usados quando o interesse do estudo focaliza a estimativa do aporte total atmosférico. Coletores de deposição apenas úmida minimizam a coleta da deposição seca e a evaporação através de uma tampa sobre o funil, que abre e fecha automaticamente no início e no fim do evento chuvoso, por um mecanismo eletrônico comandado por um sensor de condutividade. A estabilidade de amostras assim coletadas aumenta também para determinadas espécies, pela exclusão de componentes terrestres t...
The environmental legacy of the lead foundry, which was shut down in 1993, continues to represent a relevant risk factor for increased blood lead levels in children, especially those presenting pica.
In the Recôncavo of Bahia (located between 12 degrees 33' and 13 degrees 10'S and 38 degrees 00'and 39 degrees 00'W), there are significant discharges of SO(2) and NO(x) due to local, industrial and urban activities. The incoming air masses from the Atlantic Ocean are enriched with seaspray, which neutralizes part of the rain acidity. The extent of seaspray neutralization of rain acidity was quantified in four sites of the region, each with different loads of seaspray. Rain samples were obtained daily at the same time, integrating the precipitation of the previous 24h, using wet-only collectors and analyzed for pH by potentiometry and for sodium by flame photometry. The amount of rain acidity in Recôncavo neutralized by seaspray ranged from <1% up to 88% and depended on the site. On average, neutralization ranged from 5% to 18%.
High quality is recommended for drinking water to prevent the transportation of pathogenic bacteria. To ensure its quality, different technologies are applied, and copper-silver ionization is used to maintain the microbiological quality. However, considering that the characteristics of this source vary in different scenarios, it was proposed to evaluate the efficacy of copper-silver ionization for the disinfection of drinking water in Tumbes, Peru. For this evaluation, the physicochemical and microbiological parameters of drinking water were tested at different lengths of copper-silver ionization treatment (10, 20 and 30 minutes). Water samples were collected from 20 houses located in urban areas of Tumbes city where Cu-Ag ionizers (Necon GmbH) were installed. The application of Cu-Ag ionization reduced the microbiological load in the water samples, keeping them below the Peruvian permissible limits (mesophilic bacteria < 500 CFU/100 mL and coliforms < 0 CFU/100 mL). However, in samples with a high microbial load and high electrical conductivity, the microbial load was not completely diminished. Cu-Ag ionization considerably improved the microbiological quality of the water, but some physical parameters, such as pH and electrical conductivity, must be taken into account to further improve the results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.