BackgroundThe increasing utilization of balloon guide catheters (BGCs) in thrombectomy therapy for ischemic stroke has led to concerns about large-bore sheaths causing vascular groin complications.Objective To retrospectively assess the impact of large large-bore sheaths and vascular closure devices on groin complication rates at a comprehensive stroke center over a 10-year period.MethodsRadiological and clinical records of patients with acute ischemic stroke who underwent mechanical endovascular therapy with an 8Fr or larger sheaths were reviewed. A groin complication was defined as the formation of a groin hematoma, retroperitoneal hematoma, femoral artery pseudoaneurysm, or the need for surgical repair. Information collected included size of sheath, type of hemostatic device, and anticoagulation status of the patient. Blood bank records were also analyzed to identify patients who may have had an undocumented blood transfusion for a groin hematoma.ResultsA total of 472 patients with acute ischemic stroke who underwent mechanical thrombectomy with a sheath and BGC sized 8Fr or larger were identified. 260 patients (55.1%) had tissue Plasminogen Activator (tPA) administered as part of stroke treatment. Vascular closure devices were used in 97.9% of cases (n=462). Two patients were identified who had definite groin complications and a further two were included as having possible complications. There was a very low rate of clinically significant groin complications (0.4–0.8%) associated with the use of large-bore sheaths.ConclusionsThese findings suggest that concerns for groin complications should not preclude the use of BGCs and large-bore sheaths in mechanical thrombectomy for acute ischemic stroke.
Background. Bacterial meningitis is a medical emergency for which prompt diagnosis and treatment are imperative to reducing the rate of death and long-term neurologic compromise. Few cases of meningitis have been reported during pregnancy, many of which had devastating outcomes for mother, neonate, or both. Case. A 38-year-old multigravida at 35 weeks of gestation presented with mental status changes, fever, and preterm contractions. Lumbar puncture revealed gram positive cocci consistent with S. pneumoniae. Patient was intubated and admitted to ICU where she was given antibiotics and adjunctive therapy with dexamethasone. Continuous fetal monitoring was utilized throughout her course of her hospitalization. Patient was discharged home after ten days in the hospital and had an uncomplicated vaginal birth after caesarean section (VBAC) at 38 weeks. Both she and the infant are doing well with no permanent neurologic sequelae. Conclusion. A review of literature indicates only isolated cases of pneumococcal meningitis being described during pregnancy. An extended period of time between onset of maternal illness and delivery appears to reduce the risk of neonatal transmission and improve both maternal and fetal outcomes.
Background: Myocardial scar assessment using late gadolinium enhancement Cardiovascular Magnetic Resonance (LGE CMR) is commonly indicated for patients with cardiac implantable electronic devices (CIEDs), however metal artifact can degrade images. We evaluated the clinical impact of LGE CMR incorporating a device-dependent metal artifact reduction strategy in patients with CIEDs. Methods: 136 CMR studies were performed in 133 consecutive patients (age 56±19 years, 69% male) with CIEDs (22% implantable loop recorders [ILRs], 40% permanent pacemakers [PPMs], 38% implantable cardioverter defibrillators [ICDs]; 42% non-MRI conditional) over 2 years, without complication. LGE imaging was tailored to the CIED, using a wideband sequence for left-sided PPMs and ICDs and conventional sequences for ILRs and right-sided PPMs, scoring segmental artifact. Diagnostic utility and impact on clinical management were scored by consensus of experts. Results: CMR provided unexpected diagnoses in 22 (16%) and changed management in 113 (83%) patients. Myocardial scar was present in 92 (68%), with other abnormalities detected in another 13%. Using conventional LGE, 43 (32%) studies were non-diagnostic (79% of defibrillators) compared to 0% using wideband LGE imaging. Wideband LGE results changed clinical management in an additional 39 (75%) defibrillator patients and 10 (19%) pacemaker patients when compared to imaging with conventional LGE sequences. Conclusion: The clinical yield from CMR using optimized LGE sequences in patients with CIEDs is high with no demonstrated clinical risk. A device-dependent LGE imaging strategy using wideband LGE is needed to achieve clinical utility especially in ICD recipients.
BackgroundPatients with cardiac pacemakers and defibrillators are disadvantaged because of poor access to MRI scans, leading to late and misdiagnosis particularly for cancer and neurological disease. New technology allied to tested protocols now allows safe MRI scanning of such patients; however, logistical barriers persist.AimTo deliver a streamlined sustainable service that provides timely MRI scans to patients with cardiac implantable electronic devices (CIEDs).MethodsPatients requested a ‘one-stop’ service for MRI, whereby devices could be reprogrammed and scans acquired at a single location and visit. To provide this ‘one-stop’ service, we trained a team including administrators, physicians, cardiac physiologists and radiographers. A standard protocol was used to prevent unnecessary request refusals and delays to scheduling. Service volume, waiting time and safety were analysed 6 months before and 2 years after service redesign. Waiting times for internal and external inpatient referrals plus time to treatment for patients on a cancer pathway were analysed.Results215 MRI scans were performed over 2 years. After service redesign, MRI provision increased six-fold to 20 times the national average with reduced waiting time from 60 to 15 days and no adverse events. Departmental throughput was maintained. 85 (40%) referrals were external. 41 (19%) inpatients were scanned, reducing bed-stay by 3 days for internal referrals. 24 (11%) scans were for suspected cancer, 83% allowed treatment within the national standard of 62 days. There was no preintervention service for either inpatients or suspected cancer investigation.ConclusionImplementation of a ‘one-stop’ service model to provide MRI for patients with CIEDs is safe, streamlined, scalable and has reduced delays making economic and clinical sense. Protocols and checklists are available at mrimypacemaker.com.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.