Objective: To adjust for dynamic insulin requirements in critically ill patients, intravenous (IV) insulin infusions allow for titration of the dose according to a prespecified algorithm. Despite the adaptability of IV insulin protocols, human involvement in dose calculation allows for error. We integrated a previously validated IV insulin calculator into our electronic health record (Epic) and instituted it in the cardiovascular intensive care unit (CVICU). We aim to describe the design of the calculator, the implementation process, and evaluate the calculator’s impact. Method: Employing an aggressive training program and user acceptance testing prior to significant elbow support at the time of institution, we successfully integrated the insulin calculator in our CVICU. We evaluated the glucometrics before and after implementation as well as nursing satisfaction following calculator implementation. Results: Overall, our implementation led to increased frequency of blood sugar at various glycemic targets, a trend toward less hypoglycemia or hyperglycemia. For severe hypoglycemia, our preintervention cohort had 0.02% of blood sugars less than 40 mg/dL but no blood sugars less than 40 mg/dL were identified in our patient’s postintervention. For the CVICU target blood glucose of 70-180 mg/dL, 87.97% blood sugars at baseline met goal compared to 91.39% at one month, 91.24% at three months, and 90.87% at six months postintervention. Conclusion: By utilizing an aggressive education campaign championing superusers and making adjustments to the calculator based on early problems that were encountered, we were able to improve glycemic control and limit glucose variability at our institution.
The current work describes an anthropomorphic beating heart phantom constructed as a tool for the assessment of technological advances in cardiac X‐ray computed tomography (CT). The phantom is comprised of a thorax, a compressor system, an ECG system, a beating heart with tortuous coronary arteries, and the option to add or remove pathologies such as aberrant beats, stents, and plaques. Initial trials with the phantom have shown its utility to assess temporal resolution, spatial resolution, radiation dose, iodine contrast, stents, and plaques.PACS numbers: 87.59.Fm, 87.57.Ce
The paper describes a cathode ray television receiving tube incorporating several unique features. The tube was designed and constructed by Dr. C. J. Davisson and was used in some of the early demonstrations of television transmission over the coaxial cable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.