The response of the cerebral circulation to exercise has been studied with transcranial Doppler ultrasound (TCD) because this modality provides continuous measurements of blood velocity and is well suited for the exercise environment. The use of TCD as an index of cerebral blood flow, however, requires the assumption that the diameter of the insonated vessel is constant. Here, we examine this assumption for rhythmic handgrip using a spectral index designed to measure trends in vessel flow. Nineteen normal subjects were studied during 5 min of volitional maximum rhythmic right handgrip at 1 Hz. TCD velocities from both middle arteries (left and right), blood pressure, and end-tidal PCO(2) were recorded every 10 s. A spectral weighted sum was also calculated as a flow index (FI). Averages were computed from the last 2 min of handgrip. Relative changes in velocity, FI, and pressure were calculated. The validity of FI was tested by comparing the change in diameter derived from equations relating flow and diameter. Mean blood pressure increased 23.8 +/- 17.8% (SD), and velocity increased 13.3 +/- 9.8% (left) and 9.6 +/- 8.3% (right). Although the mean change in FI was small [2.0 +/- 18. 2% (left) and 4.7 +/- 29.7% (right)], the variation was high: some subjects showed a significant increase in FI and others a significant decrease. Diameter estimates from two equations relating flow and luminal area were not significantly different. Decreases in FI were associated with estimated diameter decreases of 10%. Our data suggest that the cerebral blood flow (CBF) response to rhythmic handgrip is heterogeneous and that middle cerebral artery flow can decrease in some subjects, in agreement with prior studies using the Kety-Schmidt technique. We speculate that the velocity increase is due to sympathetically mediated vasoconstriction rather than a ubiquitous flow increase. Our data suggest that the use of ordinary TCD velocities to interpret the CBF response during exercise may be invalid.
Although transcranial Doppler ultrasound (TCD) has been used to detect oscillations in CBF, interpretation is severely limited, since only blood velocity and not flow is measured. Oscillations in vessel diameter could, therefore, mask or alter the detection of those in flow by TCD velocities. In this report, the authors use a TCD-derived index of flow to detect and quantify oscillations of CBF in humans at rest. A flow index (FI) was calculated from TCD spectra by averaging the intensity weighted mean in a beat-by-beat manner over 10 seconds. Both FI and TCD velocity were measured in 16 studies of eight normal subjects at rest every 10 seconds for 20 minutes. End tidal CO2 and blood pressure were obtained simultaneously in six of these studies. The TCD probe position was meticulously held constant. An index of vessel area was calculated by dividing FI by velocity. Spectral estimations were obtained using the Welch method. Spectral peaks were defined as peaks greater than 2 dB above background. The frequencies and magnitudes of spectral peaks of FI, velocity, blood pressure, and CO2 were compared with t tests. The Kolmogorov-Smirnov test was used to further confirm that the data were not white noise. In most cases, three spectral peaks (a, b, c) could be identified, corresponding to periods of 208+/-93, 59+/-31, and 28+/-4 (SD) seconds for FI, and 196+/-83, 57+/-20, and 28+/-6, (SD) seconds for velocity. The magnitudes of the spectral peaks for FI were significantly greater (P<0.02) than those for velocity. These magnitudes corresponded to variations of at least 15.6%, 9.8%, and 6.8% for FI, and 4.8%, 4.2%, and 2.8% for velocity. The frequencies of the spectral peaks of CO2 were similar to those of FI with periods of 213+/-100, 60+/-46, and 28+/-3.6 (SD) seconds. However, the CO2 spectral peak magnitudes were small, with an estimated maximal effect on CBF of (+/-) 2.5+/-0.98, 1.5+/-0.54, and 1.1+/-0.31 (SD) percent. The frequencies of the blood pressure spectral peaks also were similar, with periods of 173+/-81, 44+/-8, and 26+/-2.5 (SD) seconds. Their magnitudes were small, corresponding to variations in blood pressure of (+/-) 2.1+/-0.55, 0.97+/-0.25, and 0.72+/-0.19 (SD) percent. Furthermore, coherence analysis showed no correlation between CO2 and FI, and only weak correlations at isolated frequencies between CO2 and velocity, blood pressure and velocity, or blood pressure and FI. The Kolmogorov-Smirnov test distinguished our data from white noise in most cases. Oscillations in vessel flow occur with significant magnitude at three distinct frequencies in normal subjects at rest and can be detected with a TCD-derived index. The presence of oscillations in blood velocity at similar frequencies but at lower magnitudes suggests that the vessel diameters oscillate in synchrony with flow. Observed variations in CO2 and blood pressure do not explain the flow oscillations. Ordinary TCD velocities severely underestimate these oscillations and so are not appropriate when small changes in flow are to be measured.
Although monitoring of blood velocity in the cerebral arteries with transcranial Doppler ultrasound is standard practice, methods for fixation of the ultrasound probe to the skull continue to impose a technical challenge. This report describes a novel method of probe fixation in which an inexpensive polymer block is custom-made for each patient to hold the probe at a fixed angle. In addition to comfort and durability, its major advantage is that the polymer block prevents dislodgment of the probe from the intended angle by forces of gravity or by patient movement. Thirty-one temporal windows were monitored with this technique, with stable signals obtained in all subjects despite aggressive movements. Disadvantages include the inability to insonate more than one vessel and the cost for each block. However, the method is quick, is relatively inexpensive, and provides significant advantages of probe stability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.