We have examined several emerging brominated flame retardants (BFRs) including 2-ethyl-1-hexyl-2,3,4,5-tetrabromobenzoate (TBB), bis(2-ethylhexyl) tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 4,5,6,7-tetrabromo-1,1,3-trimethyl-3-(2,3,4,5-tetrabromophenyl)-indane (OBIND), and decabromodiphenyl ethane (DBDPE) in paired human maternal serum (n = 102) and breast milk (n = 105) collected in 2008–2009 in the Sherbrooke region in Canada. Three legacy BFRs were also included in the study for comparison: decabromobiphenyl (BB-209), 2,2′,4,4′,5,5′-hexabromobiphenyl (BB-153), and 2,2′,4,4′,5,5′-hexabromodiphenyl ethers (BDE-153). TBB, BB-153, and BDE-153 had detection frequencies greater than 55% in both serum and milk samples. Their lipid weight (lw) adjusted median concentrations (ng g–1 lw) in serum and milk were 1.6 and 0.41 for TBB, 0.48 and 0.31 for BB-153, and 1.5 and 4.4 for BDE-153, respectively. The detection frequencies for the other BFRs measured in serum and milk were 16.7% and 32.4% for TBPH, 3.9% and 0.0% for BTBPE, 2.0% and 0.0% for BB-209, 9.8% and 1.0% for OBIND, and 5.9% and 8.6% for DBDPE. The ratio of TBB over the sum of TBB and TBPH (fTBB) in serum (0.23) was lower than that in milk (0.46), indicating TBB has a larger tendency than TBPH to be redistributed from blood to milk. Overall, these data confirm the presence of non-PBDE BFRs in humans, and the need to better understand their sources, routes of exposure, and potential human health effects.
This paper describes a project sponsored by the Canadian Mining Industry Research Organisation (CAMIRO) to evaluate the strengths and weaknesses of portable XRF for use in mineral exploration and mining and to develop best-practice protocols in the analysis of rocks, soils, sediments and drill-core. Phase I focussed on the analysis of pulp control reference materials (CRMs) to determine the figures of merit, principally accuracy and precision, of the technique before introducing the confounding parameters associated with in-situ analysis such as heterogeneity, particle size and moisture.Five instruments (three handheld and two portable benchtop) from three manufacturers were used to carry out replicate analyses (n = 10) of a diverse suite of 41 CRMs, from barren granites, through soils and sediments, to ores. Standard factory calibration, in mining and soil modes, was used. The performance of the instruments was evaluated using x-y plots of results versus established element concentrations for the CRMs and the values of goodness of fit (r 2 ), slope and intercept documented for both full and restricted concentration ranges.For many elements, the performance across the instruments varied markedly, as did the ability to correct for spectral interferences. Numerous interferences were encountered, particularly from the rare-earth elements (REEs) on transition elements, but also for well-known interference pairs such as Pb on As, Zn on Au, U on Mo, and Th on Bi. In general, major elements with the exception of the light element Mg were well determined, as were Mn and Ti. Sensitivity was inadequate for Cl and P; however, S could be measured with acceptable precision to c. 0.05% S. Performance for the trace elements was categorized as follows: very good for As, Cu, Nb, Pb, Rb, Sr, and Y (r 2 >0.9 for more than 1 instrument); good for Ba, Mo, Sn, Zn and Zr (r 2 >0.9 for 1 instrument); moderate for Cr, Sb, Se, Th and U (r 2 = 0.6-0.8); poor for Ag, Cd, Co, Ni and V; and very poor for Au, Bi, Cs, Hf, Hg, Pd, Sc, Ta, Te and W. Of the REEs determined (La, Ce, Nd, Sm, using the standard calibration by the manufacturer, i.e. not REE-specific), only La showed adequate sensitivity and precision (3-5% RSD), however, only at concentrations approaching c. 1000 ppm (50-100% RSD at La <100 ppm).Slopes of the best-fit lines, where r 2 ≥0.6, ranged from 0.5 to 5.0, indicating that calibration is required by the user for both the soil and mining modes. The precision, shown by 10 replicate readings, was excellent and usually better than 10% RSD except where close to detection limit or where major interferences were present.The beam time study showed that, in most situations, 60 s was a good compromise between productivity and precision but also highlighted cases of significant drift and a lack of improvement in precision with longer beam time. A study of the thin-film sample cover used for cups demonstrated that 4.0-µm Prolene® is superior to the same thickness of Mylar® in both transmittance (especially for Mg, Al, Si) and co...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.