Background: It has been a decade since the year 2007 was dedicated towards painless motherhood. However the use and acceptance of labor analgesia is still very rare in developing countries. Objective: The present study was aimed to assess the knowledge, acceptance and reasons for rejection of labor analgesia among the expectant mothers. Methods: The present observational study was conducted after approval from the institute. All
Background: 55 BHU bicentric bipolar hemiarthroplasties were reviewed after a mean follow up of 4 years (range 1-5 years). Patients with displaced subcapital fractures were selected for operation on the basis of good mobility before the fracture. Object of the study was to see the efficacy of BHU bipolar prostheses and functional outcome.
Objective
This study was done to evaluate myocardial function by 2D Echocardiography and Cardiac biomarkers (cTnI, CK-MB, BNP) changes in patients of scorpion envenomation of grade II-IV and correlate mortality of envenomed children with myocardial dysfunction.
Methods
A total of 40 patients admitted consecutively with grade II and more scorpion envenomation from October 2015 to July2018 were enrolled in the study. The data included demographics, the time of presentation, clinical features, echocardiographic findings, electrocardiographic findings, cardiac biomarker levels at admission and discharge, use of inotropic medication, oral prazosin, time of discharge, and their outcome.
Results
The most common ECG abnormality was sinus tachycardia 28 (70%) followed by low voltage complex 13 (32.5%) which got normalized at the time of discharge in majority. Cardiac troponin I (cTnI) levels were more than 0.1 ng/mL, suggesting myocarditis was present in 25 (62.5%) and got normalized at discharge. CK-MB levels were increased in 26 (65%) patients suggesting myocardial involvement. BNP levels were also increased in 24 (60%) patients suggesting heart failure and its value got normalized at discharge. Abnormal 2D Echo findings as reduced left ventricular ejection fraction (LVEF) was present in 18 (45%) cases suggesting myocardial dysfunction and became normal at discharge. The sensitivity, specificity, positive predictive value and negative predictive value of Cardiac troponin I (cTnI) considering ECHO cardiograph as gold standard were 100, 68.1, 72 and 100% respectively. One patient had died whose Ejection fraction was less than 30%.
Conclusion
Echocardiography and cTnI can identify subgroup of patients, who require early aggressive therapy. Echocardiography, if not available, cardiac troponin I level can guide early therapy and indicates the prognosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.