Context:
Lower degree of conversion (DC%) of monomer to polymer in a resin composite restoration could be a health hazard for the patient as well as it could affect the longevity of the restoration.
Aims:
This study is aimed to compare and evaluate the DC% of four different composites polymerized using ultrafast photopolymerization.
Settings and Design:
In-vitro
study.
Materials and Methods:
A total of 40 disc-shaped composite samples were used in the study. Twenty samples were prepared for each group using 2 mm height and 6 mm diameter Tygon tube as a matrix. All of the composites were cured using the Woodpecker i Led light-curing unit with an intensity of 2300–2500 mW/cm
2
(TURBO mode). Samples in Group 1 were cured for 1 s and samples in Group 2 were cured for 3 s. Each group had 4 subgroups of five samples of the 4 resin composites tested. After photo-activation, the specimens were stored under dark dry conditions at room temperature for 24 h before testing. The DC% was measured using Fourier-transform infrared spectroscopy.
Statistical Analysis Used:
The DC% were analyzed using ANOVA, and Tukey HSD
post hoc
test using IBM SPSS 21 software.
Results:
Among the experimental groups, Group 2 showed a higher DC% which ranges from 93.7% to 95.4% than Group 1 which ranges from 58.5% to 65.5%. There was a statistically significant difference in the DC% among the materials tested (
P
< 0.05).
Conclusions:
Within the limitations of the study, it was concluded that composites cured for 3 s showed a higher DC% which ranges from 93.7% to 95.4% than those cured for 1 s. The DC% also varied among the four different composites tested.
A structure is an assembly of various elements or components which are fastened together through some type of connections. Steel beam column connection may fail due to large earth quake. Plastic hinge formation is the main failure of a steel beam column connection. There are two methods for improving the steel beam column connection (i) connection reinforcement/strengthening (ii) beam weakening by reducing the cross-sectional area of the beam at a certain distance from the connection. When reducing the cross section area plastic hinge is formed away from column face. The main objective of this study is to compare reduced beam section (RBS) and reduced web section (RWS) pattern and find out the location of plastic hinge. For steel beam column plastic hinge is located near column. When reducing the cross section area the location of plastic hinge will shift from the column. Aim of this project is to locate the position of plastic hinge apart from column face, and also evaluate the stress and deformation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.