Congenital adrenal hyperplasia (CAH) is a severe inherited disorder of cortisol biosynthesis that is potentially lethal or can seriously affect quality of life. For the first time, we aimed to assess the stability of 21-deoxycortisol (21Deox), 11-deoxycortisol (11Deox), 4-androstenedione (4AD), 17-hydroxyprogesterone (17OHP) and cortisol (Cort), diagnostic for CAH, in dried blood spots (DBSs) during a 1 year storage at different temperatures. Spiked DBS samples were stored at room temperature, 4˚C, -20˚C or -70˚C, respectively and analyzed in triplicates using liquid chromatography-tandem mass spectrometry at Weeks 0, 1, 2, 3 and 4, Month 6 and Year 1. Analyte levels within ±15% vs the baseline were considered stable. Our observations show that 21Deox, 4AD and 17OHP were not significantly changed for 1 year even at room temperature at either analyte levels. In contrast, Cort required storage at 4˚C, -20˚C or -70˚C for long-term stability, being significantly decreased at room temperature from Month 6 (p<0.01) in both the 30(60) nM and the 90(180) nM samples. 11Deox was significantly decreased at room temperature at Year 1 (p<0.01) and only in the 30(60) nM samples. Thus, all biomarkers were stable for up to 1 year at 4˚C, -20˚C or -70 C and at least for 4 weeks at room temperature. These findings have implications for analyses of stored DBS samples in 2 nd -tier assays in newborn screening and for retrospective CAH studies.
In newborn screening, samples suspected for congenital adrenal hyperplasia (CAH), a potentially lethal inborn error of steroid biosynthesis, need to be confirmed using liquid chromatography–tandem mass spectrometry. Daily quality controls (QCs) for the 2nd-tier CAH assay are not commercially available and are therefore generally prepared within the laboratory. For the first time, we aimed to compare five different QC preparation approaches used in routine diagnostics for CAH on the concentrations of cortisol, 21-deoxycortisol, 11-deoxycortisol, 4-androstenedione and 17-hydroxyprogesterone in dried blood spots. The techniques from Prep1 to Prep5 were tested at two analyte concentrations by spiking aliquots of a steroid-depleted blood, derived from washed erythrocyte suspension and steroid-depleted serum. The preparation processes differed in the sequence of the preparation steps and whether freeze-thaw cycles were used to facilitate blood homogeneity. The five types of dried blood spot QCs were assayed and quantitated in duplicate on five different days using a single calibration row per day. Inter-assay variations less than 15% and concentrations within ±15% of the nominal values were considered acceptable. Results obtained by means of the four dried blood spot QC preparation techniques (Prep1, Prep2, Prep4 and Prep5) were statistically similar and remained within the ±15% ranges in terms of both reproducibility and nominal values. However, concentration results for Prep3 (spiking prior to three freeze-thaw cycles) were significantly lower than the nominal values in this setting, with differences exceeding the ±15% range in many cases despite acceptable inter-assay variations. These findings have implications for the in-house preparation of QC samples in laboratory developed tests for CAH, including 2nd-tier assays in newborn screening.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.