Real-time nucleic acid sequence-based amplification (NASBA) is an isothermal method specifically designed for amplification of RNA. Fluorescent molecular beacon probes enable real-time monitoring of the amplification process. Successful identification, utilizing the real-time NASBA technology, was performed on a microchip with oligonucleotides at a concentration of 1.0 and 0.1 microM, in 10- and 50-nL reaction chambers, respectively. The microchip was developed in a silicon-glass structure. An instrument providing thermal control and an optical detection system was built for amplification readout. Experimental results demonstrate distinct amplification processes. Miniaturized real-time NASBA in microchips makes high-throughput diagnostics of bacteria, viruses, and cancer markers possible, at reduced cost and without contamination.
A general multipurpose microchip technology platform for point-of-care diagnostics has been developed. Real-time nucleic acid sequence-based amplification (NASBA) for detection of artificial human papilloma virus (HPV) 16 sequences and SiHa cell line samples was successfully performed in cyclic olefin copolymer (COC) microchips, incorporating supply channels and parallel reaction channels. Samples were distributed into 10 parallel reaction channels, and signals were simultaneously detected in 80 nl volumes. With a custom-made optical detection unit, the system reached a sensitivity limit of 10(-6) microM for artificial HPV 16 sequences, and 20 cells microl(-1) for the SiHa cell line. This is comparable to the detection limit of conventional readers, and clinical testing of biological samples in polymer microchips using NASBA is therefore possible.
A Lab-On-Chip system with an instrument is presented which is capable of performing total sample preparation and automated extraction of nucleic acid from human cell samples fixed in a methanol based solution. The target application is extraction of mRNA from cervical liquid based cytology specimens for detection of transformed HPV-infections. The device accepts 3 ml of sample and performs the extraction in a disposable polymer chip of credit card size. All necessary reagents for cell lysis, washing, and elution are stored on-chip and the extraction is performed in two filter stages; one for cell pre-concentration and the other for nucleic acid capture. Tests performed using cancer cell lines and cervical liquid based cytology specimens confirm the extraction of HPV-mRNA by the system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.