Almost all hospitals use radioisotopes for different purposes, as their applications grow, so their concentration in the waste of those hospitals does. To address this issue, twenty-nine samples were collected from (9) sites, these samples were collected from the incinerators of medical areas and the waste collection chambers. After collecting the samples, they were prepared for the examination, where a high-purity Germanium detector (HPGe) was used to detect radioactive elements. The lead element (Pb-214) of the uranium chain (U-238) and the actinium element (Ac-228), the lead element (Pb-212) of the thorium chain (Th-246) and the potassium element (K-40) appeared in some medical areas Iodine (I-131). Some regions showed high concentrations of these elements compared to some sites, Iodine (I-131) appeared in high rates in some hospitals specialized in treating cancerous diseases. The equivalent efficacy of radium, the annual equivalent internal and external dose, and the internal and external risk factors were calculated and the results obtained were compared with the global limits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.