ObjectiveKnowledge of the breastfeeding swallow is limited by practical challenges. Radiation exposure to both mother and infant and the radiolucent properties of breastmilk make videofluoroscopy an unsuitable imaging modality. Furthermore, ultrasound is not ideal for capturing the complex 3‐dimensional functional anatomy of swallowing. In this study we explore the feasibility of using real‐time MRI to capture the breastfeeding swallow.MethodsProspective observational study: Review of imaging from 12 normal infants (<5 months of age) and their mothers while breastfeeding using real‐time MRI.ResultsStatic images were successfully captured in 11 infants and dynamic images in nine infants. This imaging modality confirms the dorsal surface of the infant's tongue elevates the maternal nipple to the hard palate, closing the space around the nipple with no air visible in the oral cavity during sucking and swallowing. We obtained dynamic imaging of mandibular movement with sucking, palatal elevation and pharyngeal constriction with swallowing, diaphragm movement with breathing and milk entering the stomach. Breastmilk was easily visualized, being high intensity on T2 sequences. Technical challenges were encountered secondary to infant movement and difficulties acquiring and maintaining midsagittal orientation. The similarity in tissue densities of the lips, tongue, nipple and hard palate limited definition between these structures.ConclusionReal‐time MRI imaging was successful in capturing dynamic images of the breastfeeding swallow. However, technical and practical challenges make real‐time MRI unlikely at present to be suitable for swallow assessment in clinical practice. Advances in technology and expertise in dynamic image capture may improve the feasibility of using MRI to understand and assess the breastfeeding swallow in the near future.Level of evidence4.
Purpose Amplified MRI (aMRI) has been introduced as a new method of detecting and visualizing pulsatile brain motion in 2D. Here, we improve aMRI by introducing a novel 3D aMRI approach. Methods 3D aMRI was developed and tested for its ability to amplify sub‐voxel motion in all three directions. In addition, 3D aMRI was qualitatively compared to 2D aMRI on multi‐slice and 3D (volumetric) balanced steady‐state free precession cine data and phase contrast (PC‐MRI) acquired on healthy volunteers at 3T. Optical flow maps and 4D animations were produced from volumetric 3D aMRI data. Results 3D aMRI exhibits better image quality and fewer motion artifacts compared to 2D aMRI. The tissue motion was seen to match that of PC‐MRI, with the predominant brain tissue displacement occurring in the cranial‐caudal direction. Optical flow maps capture the brain tissue motion and display the physical change in shape of the ventricles by the relative movement of the surrounding tissues. The 4D animations show the complete brain tissue and cerebrospinal fluid (CSF) motion, helping to highlight the “piston‐like” motion of the ventricles. Conclusions Here, we introduce a novel 3D aMRI approach that enables one to visualize amplified cardiac‐ and CSF‐induced brain motion in striking detail. 3D aMRI captures brain motion with better image quality than 2D aMRI and supports a larger amplification factor. The optical flow maps and 4D animations of 3D aMRI may open up exciting applications for neurological diseases that affect the biomechanics of the brain and brain fluids.
Fetal growth restriction (FGR) and maternal supine going‐to‐sleep position are both risk factors for late stillbirth. This study aimed to use magnetic resonance imaging (MRI) to quantify the effect of maternal supine position on maternal‐placental and fetoplacental blood flow, placental oxygen transfer and fetal oxygenation in FGR and healthy pregnancies. Twelve women with FGR and 27 women with healthy pregnancies at 34–38 weeks’ gestation underwent MRI in both left lateral and supine positions. Phase‐contrast MRI and a functional MRI technique (DECIDE) were used to measure blood flow in the maternal internal iliac arteries (IIAs) and umbilical vein (UV), placental oxygen transfer (placental flux), fetal oxygen saturation (FO2), and fetal oxygen delivery (delivery flux). The presence of FGR, compared to healthy pregnancies, was associated with a 7.8% lower FO2 (P = 0.02), reduced placental flux, and reduced delivery flux. Maternal supine positioning caused a 3.8% reduction in FO2 (P = 0.001), and significant reductions in total IIA flow, placental flux, UV flow and delivery flux compared to maternal left lateral position. The effect of maternal supine position on fetal oxygen delivery was independent of FGR pregnancy, meaning that supine positioning has an additive effect of reducing fetal oxygenation further in women with FGR, compared to women with appropriately grown for age pregnancies. Meanwhile, the effect of maternal supine positioning on placental oxygen transfer was not independent of the effect of FGR. Therefore, growth‐restricted fetuses, which are chronically hypoxaemic, experience a relatively greater decline in oxygen transfer when mothers lie supine in late gestation compared to appropriately growing fetuses. imageKey points Fetal growth restriction (FGR) is the most common risk factor associated with stillbirth, and early recognition and timely delivery is vital to reduce this risk. Maternal supine going‐to‐sleep position is found to increase the risk of late stillbirth but when combined with having a FGR pregnancy, maternal supine position leads to 15 times greater odds of stillbirth compared to supine sleeping with appropriately grown for age (AGA) pregnancies. Using MRI, this study quantifies the chronic hypoxaemia experienced by growth‐restricted fetuses due to 13.5% lower placental oxygen transfer and 26% lower fetal oxygen delivery compared to AGA fetuses. With maternal supine positioning, there is a 23% reduction in maternal‐placental blood flow and a further 14% reduction in fetal oxygen delivery for both FGR and AGA pregnancies, but this effect is proportionally greater for growth‐restricted fetuses. This knowledge emphasises the importance of avoiding supine positioning in late pregnancy, particularly for vulnerable FGR pregnancies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.