Purpose To assess surgical and safety outcomes associated with different rod materials and diameters in adolescent idiopathic scoliosis (AIS) surgery. Methods A systematic literature review and meta-analysis evaluated the surgical management of AIS patients using pedicle screw fixation systems (i.e., posterior rods and pedicle screws) with rods of different materials and sizes. Postoperative surgical outcomes (e.g., kyphosis and coronal correction) and complications (i.e., hyper/hypo-lumbar lordosis, proximal junctional kyphosis, revisions, reoperations, and infections) were assessed. Random-effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. Results Among 75 studies evaluating AIS surgery using pedicle screw fixation systems, 46 described rod materials and/or diameters. Two studies directly comparing titanium (Ti) and cobalt–chromium (CoCr) rods found that CoCr rods provided significantly better postoperative kyphosis angle correction vs. Ti rods during a shorter follow-up (0–3 months, MD = − 2.98°, 95% CI − 5.79 to − 0.17°, p = 0.04), and longer follow-up (≥ 24 months, MD = − 3.99°, 95% CI − 6.98 to − 1.00, p = 0.009). Surgical infection varied from 2% (95% CI 1.0–3.0%) for 5.5 mm rods to 4% (95% CI 2.0–7.0%) for 6 mm rods. Reoperation rates were lower with 5.5 mm rods 1% (95% CI 0.0–3.0%) vs. 6 mm rods [6% (95% CI 2.0–9.0%); p = 0.04]. Differences in coronal angle, lumbar lordosis, proximal junctional kyphosis, revisions, and infections did not differ significantly (p > 0.05) among rods of different materials or diameters. Conclusion For AIS, CoCr rods provided better correction of thoracic kyphosis compared to Ti rods. Patients with 5.5 mm rods had fewer reoperations vs. 6.0 and 6.35 mm diameter rods. Level of evidence III.
Purpose To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. Methods A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. Results Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt–chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°–55.42°] and Ti 32.58° [24.62°–40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°–29.53°] and Ti 20.15° [18.0°–22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7–22%) for CoCr and 12% (− 8–32%) for stainless steel (SS) (n = 2 studies each; Chi2 = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1–22%) for Ti (n = 3 studies) and 10% (2–19) for CoCr (n = 1 study). Among 6.0–6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°–14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°–40.62°), and pelvic tilt angle was 21.11° (18.35°–23.86°). Conclusions For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided. Level of Evidence III
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.